Configuring A Server That Has Acu Installed - HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference Manual

Smart array controllers configuring arrays
Table of Contents

Advertisement

Configuring a server that has ACU installed

Click Start, and then select Programs>HP System Tools>HP Array Configuration Utility>Setup HP
1.
Array Configuration Utility.
The Execution Mode screen appears.
If Local Application Mode is selected, continue with step 2.
o
If Remote Service Mode is selected, select Local Application Mode, reboot the server, and then
o
continue with step 2.
Click Start, and then select Programs>HP System Tools>HP Array Configuration Utility.
2.
The browser opens and launches ACU, which then scans the system and detects controllers. This
process can last up to 2 minutes. When controller detection is complete, the controllers are available
on the Controller/Device menu.
Select a controller from the Controller/Device menu.
3.
The Configuration screen appears.
Configure the controller:
4.
To configure manually, see "Performing a Configuration task (on page 42)."
o
To configure with a wizard, see "Using Wizards (on page 51)" or "Using Express Configuration
o
(on page 52)."
When prompted, save the configuration.
5.
Do one of the following:
6.
Configure an additional controller. Repeat steps 3 through 5.
o
Click Exit ACU.
o
If you changed to Local Application mode in step 1, and you are finished configuring arrays on this
7.
server, do the following:
HP Array Configuration Utility 22

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents