HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference Manual page 83

Smart array controllers configuring arrays
Table of Contents

Advertisement

Method mode
Custom
Auto
Logical Drive category
The Logical Drive category has the following options:
ArrayAccelerator (on page 83)
LogicalDrive (on page 83)
LogicalDriveSSPState (on page 84)
ParityGroups (on page 84)
PreferredPath (on page 84)
RAID (on page 84)
Sectors (on page 84)
Size (on page 85)
SSPAdaptersWithAccess (on page 85)
StripeSize (on page 85)
ArrayAccelerator
This option specifies whether the array accelerator is enabled or disabled for the specified logical drive.
The default value is Enabled.
LogicalDrive
The value that you enter for this option specifies the ID number of the logical drive that is to be created or
modified. The first logical drive on an array must have an ID of 1 (not 0), and logical drive numbering
must be contiguous.
In Configure action mode, ACU accepts only the ID number of the next possible logical drive.
In Reconfigure action mode, ACU also accepts the ID number of any existing logical drive.
Possible values
To specify exactly which drives to use as
spares, use the applicable convention (port:ID,
box:bay, or port:box:bay).
To specify only the number of spares (not the
exact IDs), enter that number as the value for
this option. ACU automatically selects only
those drives that are suitable for the array.
To specify that the array should not have
spares, enter None.
Yes (indicating one spare)
No
Default value
In Configure action mode: None
In Reconfigure action mode, ACU
ignores any value entered for this
option and keeps any spares that
are already present in the
configuration
In Configure action mode: Yes
(indicating one spare)
In Reconfigure action mode, ACU
ignores any value entered for this
option and keeps any spares that
are already present in the
configuration
HP Array Configuration Utility 83

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents