NOTE:
You must increase timeout values for Emulex single path (without multipath support) and QLogic
single path used in this environment. This is important for both online upgrades and general
data integrity.
Online controller software upgrades are not supported with Xen Citrix boot devices.

Managing application I/O timeouts for an online upgrade

Applications are typically insulated from the online controller software upgrade by the operating
system and HBA driver software. Consequently, if the application is running on a properly configured
operating system, the online controller software upgrade will complete successfully. Evaluate any
applications that have more stringent timeout requirements than the operating system to help
determine if the applications will tolerate the online upgrade. Although an application may survive
the online controller software upgrade successfully, there may be an impact on performance. To
minimize the performance impact on users, perform the online upgrade during a period of low
user activity.

Managing external devices

If the array is being used as external storage (virtualized behind an HP P9000 XP array), perform
the following resets before doing the upgrade (you will reset them after the upgrade is complete):
IMPORTANT:
Enable System Option Mode 725 on the XP
Set the I/O Timeout to 240 seconds on all applicable external paths
Set the Path Blockade Watch Timer to 180 seconds on all applicable external paths
Once the upgrade is complete, reset these parameters to their original values.

Managing an SVSP configuration for an online upgrade

If the array is in an SVSP configuration with SVSP synchronous mirrors, see the HP SAN Virtualization
Services Platform Best Practices Guide for more information before upgrading. This document is
available at http://www.hp.com/support/manuals. Select Storage Software under storage and
then select HP SAN Virtualization Services Platform under Storage Virtualization Software.

Backing up all array data

Estimated time to complete: Varies
When to perform: As close as possible to the upgrade
Before starting the upgrade, HP recommends that you perform a full verified backup of all array
data. Although not required, it is a best practice to back up your data before performing major
operations such as software upgrades. Schedule the backup as close to the upgrade as possible.
For more information about establishing and implementing backup procedures for the array, contact
your HP sales representative.
TIP:
If using server-based management, HP recommends that you also back up the management
server before you begin the upgrade.

Upgrading HP P6000 Command View

Estimated time to complete: 15–20 minutes or longer, depending on your configuration
When to perform: Anytime before the upgrade
Vraid0 LUNs on the XP array are not supported during an upgrade.