to Managed Mode. The chapter "Starting and Configuring the Dell™PowerConnect™
2708/2716/2724/2748 for Managed Mode Operation" explains how to set the switch to Managed
Mode.

Site Requirements

The PowerConnect 2708/2716/2724/2748 devices can be mounted in a standard equipment rack,
placed on a tabletop, or mounted on the wall.
Before installing the unit, verify that the site selected for the device meets the following site
requirements:
Power — The device is installed within 1.5 m (5 feet) of a grounded, easily accessible outlet
220/110 VAC, 50/60 Hz. If the device has two power supplies, the site should have two power
outlets with different power feeders.
General — Ensure that the power supply is correctly installed.
Clearance — There is adequate frontal clearance for operator access. Allow clearance for
cabling, power connections, and ventilation.
Cabling — Cabling is routed to avoid sources of electrical noise such as radio transmitters,
broadcast amplifiers, power lines, and fluorescent lighting fixtures.
Ambient Requirements — The ambient unit operating temperature range is 0 to 45C (32 to
113F) at a relative humidity of up to 95%, non-condensing. Verify that water or moisture
cannot enter the device case.

Unpacking

NOTE:
immediately to Dell.

Safety

CAUTION:
attached.
Figure 3-1. Caution Label
CAUTION:
this label attached. There are no serviceable parts inside these components. If you suspect a problem
with one of these parts, contact a service technician.
26
Before unpacking the device, inspect the packaging and report any evidence of damage
Never remove the cover on a power supply or any part that has the following label
Hazardous voltage, current, and energy levels are present inside any component that has