Download Print this page

NEC NP-M311W Command Manual page 16

Rs232 codes- projectors
Hide thumbs Also See for NP-M311W:

Advertisement

DATA05
Cooling processing
00H: No execution (Normal condition)
01H: During execution
DATA06
Indication signal number (Entry list number - 1)
0 .. 199
DATA07
Type 1 of input terminal to be selected (!)
01H : 1
02H : 2
03H : 3
04H : 4
05H : 5
DATA08
Type 2 of input terminal to be selected (!1) (!) (!!)
01H : RGB (*5)
02H : VIDEO
03H : S-VIDEO
04H : COMPONENT
05H : Reserved
06H : DIGITAL (*6)
07H : VIEWER
08H : SLOT1
09H : SLOT2
DATA09
Indication signal type
* Valid only when Type 2 of input terminal is 02H or 03H
x0H : NTSC3.58
x1H : NTSC4.43
x2H : PAL
x3H : PAL60
x4H : SECAM
x5H : B/W60
x6H : B/W50
x7H : PALNM
x8H : NTSC3.58 LBX
x9H : NTSC3.58 SQZ
xDH : NTSC
xEH : PAL-M
xFH : PAL-N
* x: undefined
DATA10 .. 12 Reserved ( undefined )
DATA13 .. 20 Horizontal frequency of the indication signal(string)
("000.00" kHz + NULL(0)+ NULL(0) )
DATA21 .. 28 Vertical frequency of the indication signal(string)
("000.00" Hz + NULL(0)+ NULL(0) )
DATA29
Picture mute
00H : OFF
01H : ON
DATA30
Sound mute
00H : OFF
01H : ON
DATA31 .. Reserved
DATA32 Freeze Status (!2)

Advertisement

loading