01H : Connected
DATA09 .. 16 Reserved
Response: At the time of a failure
A0H 85H 01H xxH 02H DATA01 DATA02 CKS
(*1)
(*2)
078-3. INPUT STATUS REQUEST
**********************************************************************
Function:
This command acquires the status of input signal of the projector.
Command:
00H 85H 00H 00H 01H 02H 88H
Response: At the time of a success
20H 85H 01H xxH 10H DATA01 .. DATA16 CKS
(*1) (*2)
Data Portion Contents
-------------------------------------------------------------------
DATA01
Selecting signal processing
00H : No execution(Normal condition)
01H : During execution
DATA02
Signal number( Entry list number - 1 )
0 .. 199
DATA03 .. 04 Selected input terminal
Terminal name
RGB1(RGB)(*5)
RGB2(*5)
DVI(Analog)
Video
S-Video
Component
Component
DVI(*6)
DVI(DIGITAL)(*6)
HDMI
Viewer
LAN
Slot1-1
Slot1-2
Slot2-1
Slot2-2
RGB(Video)
RGB(S-Video)
DATA05
Entry list type
01H : Default
02H : User
(*4)
(*3)
(*3)
DATA03 DATA04
01H
01H
02H
01H
02H
01H
01H
02H
01H
03H
02H
04H
03H
04H
01H
06H
01H
06H
01H
06H
01H
07H
02H
07H
01H
08H
02H
08H
01H
09H
02H
09H
02H
02H
02H
03H