(!1) X = 100 - ((Lamp Use Prohibited Time * 100) / Lamp Use Warning Starting Time)
Example) The case of Lamp Use Prohibited Time 2100[H] A
Lamp Use Warning Starting Time 2000[H] Model.
X = 100 - ((2100 * 100) / 2000) = -5[%]
(!2) Lamp Hour Meter
This is the timer for normal lamp mode conversion.
(!3) Lamp usage time
This is the lamp total usage. It is displayed in the projector's menu.
(!4) This setting is ignored, if the Item's unit is not time.
(!5) NP4000/4001, NP4100/4100W : This function is not supported.
038. LAMP MODE REQUEST
**********************************************************************
Function:
This command acquires the setting of the lamp mode of projector.
Command:
03H B0H 00H 00H 01H 07H BBH
Response: At the time of a success
23H B0H 01H xxH 02H DATA01 DATA02 CKS
(*1)
(*2)
Data Portion
Contents
-----------------------------------------------------------------
DATA01
07H fixed
DATA02
Setting Value
00H : Normal
01H : Eco
Response: At the time of a failure
A3H B0H 01H xxH 02H DATA01 DATA02 CKS
(*1)
(*2)
039. LAMP MODE SET
**********************************************************************
Function:
This command sets the lamp mode of projector.
Command:
03H B1H 00H 00H 02H DATA01 DATA02 CKS
Data Portion
Contents
-----------------------------------------------------------------
DATA01
07H fixed
DATA02
Setting Value
00H : Normal
01H : Eco
Response: At the time of a success
23H B1H 01H xxH 02H DATA01 DATA02 CKS
(*1)
(*2)
Data Portion
Contents
-----------------------------------------------------------------
(*3)
(*4)
(*3)
(*3)
(*3)

Advertisement