Chapter 4

Hot Swap Subsystem SCSI Address Settings

Switches 3 and 4 determine the SCSI ID for each shelf in the hot swap
subsystem. Table 4-2 lists the possible IDs.
NOTE
For information on changing the CD-ROM drive SCSI address
setting, see the Technical Information Label on the CD-ROM
drive.
Table 4-2. Hot-Swap Shelf SCSI Address Settings
Switch
3
Off
Off
On
On
4
SCSI Address
Off
Shelf 1 = ID 1
Shelf 2 = ID 2
Shelf 3 = ID 3
On
Shelf 1 = ID 1
Shelf 2 = ID 0
Shelf 3 = ID 3
Off
Shelf 1 = ID 9
Shelf 2 = ID 10
Shelf 3 = ID 11
On
Shelf 1 = ID 9
Shelf 2 = ID 8
Shelf 3 = ID 11