Chapter 2
Ensure the monitor cables and mouse cables are long enough to allow the
NetServer to be extended at the same time the keyboard tray is pulled out.
Use locally available extensions if necessary.
The mounting distances provided in rack configuration tools assume cables
between the servers and connected devices provide for the Cable
Management Arm (for the LXr 8500).

Cooling Requirements for the LXr 8500

The HP NetServer LXr 8500 should be kept at an operating temperature between
68 and 72 degrees F.
Because of the heat generated by the HP NetServer LXr 8500, both the front and
rear doors of the rack have perforated surfaces. Air flow in the rack enters units
through front panels and leaves through the rear. If you are installing the HP
NetServer LXr 8500 in a rack that does not have front and rear perforated doors,
replace the doors on your rack with perforated doors to ensure proper cooling.
Because of the high capacity fans installed in the HP NetServer LXr 8500, no
external exhaust fan is needed with this unit. The rack must have perforated front
and rear doors.
26
Rack Cabling References