1.28 Latch

(1) Remove the latch from the paper feed guide upper by releasing the 2 hooks.

1.29 Fixing unit (for both 120V and 230V, the only difference is the halogen heater)

(The fixing unit can be disassembled even after removing the rear cover in section 1.6).
(1) Release the hook of the heater lead wire connector (2P) by pinching the connector and pull it
out upward (to remove it from the low-voltage power supply assy).
(2) Pull out the fixing PCB connector (4P) to the rear ( A ).
(3) Loosen the 2 screws which are securing from the rear, and remove the fixing unit by pulling it
to the rear.
Heater lead wire
Connector (2P)
Screw
Paper feed guide upper
Hook
Hook
Figure 4.46
Fixing unit
Figure 4.47
IV - 19
Latch
A
Connector (4P)
Screw