4. Installing the angle
adjustment unit
1. Pass the wiring cables
through the pipe, then insert
the angle adjustment unit
into the ceiling mount unit.
Adjust the height so that the
red mark on the pipe is not
visible and then insert the
two coupling pins.
Have two coupling pins
inserted into the linkage
holes in the angle adjustment
unit.
2. Insert snap pins into the
holes in the ends of the
coupling pins.
3. Tighten the 4 lock screws.
4. Adjust the horizontal angle of
the screen.
5. Tighten the one rotation
stopper screw.
Mounting the display mounting fittings on the plasma display
CMP401X
1. Remove the stand.
1. Place a protective sheet cover on the top of a
table and place the plasma display on the cover
with the back side upward.
2. Remove the screws fastening the column and pull
the column out in the direction indicated by the
arrow
mark.
Column
Stand
Table
Ceiling mount unit
3.Tighten the
4 lock screws.
1.Insert the
2 coupling pins
This could cause the
plasma display to fall
if it is assembled to
make the red mark
visible.
Remove the screws.
CMP401X plasma
display
Red mark
3. Remove the 4 screws fastening the stand and
remove the stand in the direction indicated by the
arrow
Stand
- 7 -
2.Insert 2 snap pins.
Linkage hole
5.Tighten the
rotation stopper
screw.
Angle adjustment unit
4.Adjust the
horizontal angle.
mark.
Remove 4 screws.