PLC-WXU300 Expand Serial Command Functional Specifications
8.10.20 CF_P-MANETIME Command
Command
"CF_P-MANETIME_%1"[CR]
"01" ~ "30" ----------------------- Directly select setting time by the minute
"UP" ------------------------------- Plus one minute (01 → 02 → ÿ e ÿ e ÿ e → 30 → 01)
ÿ ÿ
"DN" ------------------------------- Minus one minute(30 → 29 → ÿ e ÿ e ÿ e → 01 → 30)
Set Power Management time
The status set by this command is stored in EEPROM and its setting is effective
Details
after ALL is OFF
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
8.10.21 CF_ON-STA Command
Command
"CF_ONÿ STA_%1"[CR]
"ON" --------------------------- Set Power On Start to ON
"OFF" ------------------------- Set Power On Start to OFF
"UP" --------------------------- Switch setting (On → Off → On → ÿ e ÿ e ÿ e )
%1
"DN" --------------------------- Switch setting (On → Off → On → ÿ e ÿ e ÿ e )
Note) "UP" and "DN" behave the same.
Set/Cancel Power ON Start
The status set by this command is stored in EEPROM and its setting is effective
Details
after ALL is OFF
This command is available in normal Power ON status and Network mode is
selected in Standby mode.
Acceptable
Response
Unacceptable
8.10.22 CF_CCAPTIONDISP Command
Command
"CF_CCAPTIONDISP_%1"[CR]
"OFF" ------------- Select Off
"CC1" ------------- Select CC1
%1
"CC2" ------------- Select CC2
"CC3" ------------- Select CC3
"CC4" ------------- Select CC4
Select channel of Closed caption.
The status set with this command is stored in EEPROM and its setting is effective
even after ALL is OFF.
This command is available in normal Power ON status.
Details
Note)Closed caption is available under conditions below;
Entered signal is appropriate (Video, NTSC signal of S-video, Component=480i)
and System is fixed to NTSC or 480i.
Acceptable
Response
Unacceptable
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]