PECm FICATIO NS
LI:REQUi R EM ENTS
The:AC m0tor is a Split Phase nomreversible type, with the
following specifications
-_ =
Horsepower
.................................
1/3
Voltage ;. ...............
" ...................
115
Ampe:res .. .......
;, :... :, ._:_:.:..i:do :.,.,..
......
6
Hertz ;.
.......................................
60
Phase. ........................
Single
Rotation (viewed from: Pulleyend);
;:_:;; ;. ;:; clockwise
Abrasive BeltSpeed: (FeeltPer Min:,)ApproXl / :: .;: . .3000
Althodghlthe-motO_:i
isdeSigr_ed
for o_rat!on
on the
voltage and frequency
Specified on m:bt0r nameplate,
normal loads wilt be handled safely on voltages not mere
than 10% abo$e or below 'the
nameplate vottage. Heavy
loads; howeVer, require that v01tage at;m0t0r terminals be
not lessthan the Voltage specified on nameplate:
CONN ECTING TO: POWER SOURCE O UTLET
This
Sander/Grinder
must
begroundedlWhile
:in
use:to
protect the operator
from
electrical
shoCk.
If power
cord is worn or cut, or damaged in any way, have
it replaced immediately,
if your
Sander/Grinder
is for use on less than: 150 volts
it
has a plug that looks like below_
3-PRONG
PLUG
e
GI_OUNDING
PRONG
PROPI]RLY
GROUNDED
3-PRONG
OUTLET
Plug power
cord
into
110-120V
properly
grounded
type
outlet
protected
by a 1S-amp.
time
delay
or Circuit-Saver
fuse or circuit
breaker.
IF
YOU ARE
NOT SURE THAT
YOUR
OUTLET
IS
PROPERLY
GROUNDED,
HAVE
IT CHECKED
BY A
QUALIFIED
ELECTRICIAN.
WARNING:
DO NOT PERMIT
FINGERS
TO
TOUCH
THE TERMINALS
OF PLUG WHEN INSTALLING
OR
REMOVING
THE PLUG TO OR FROM THE OUTLET.
WARNING:
IF
NOT
PROPERLY
GROUNDED
THIS
POWER TOOL CAN INCUR THE POTENTIAL
HAZARD
OF
ELECTRICAL
SHOCK;
PARTICULARLY
WHEN
USED
IN
DAMP
LOCATIONS,/
IN
PROXIMITY
TO
PLUMBING,
OR OUT OF DOORS. IF AN ELECTRICAL
SHOCK
OCCURS THERE
IS THE
POTENTIAL
OF A
SECONDARY
HAZARD
SUCH
AS
YOUR
HANDS
CONTACTING
THE
ABRASIVE
BELT OR DISC.
This
SandertGrinder
is equipped
with
a 3-conductor
cord
and
grounding
type
plug
which
has a grounding
prong,
approved
by
Underwriters
_ Laboratories
and the Canadian
Standards
Association.
The
ground
conductor
has a green
lug and is attached
tO the tool
housing
at one end and to the
ground prong in the attachment
plug at the other
end.
This
plug
requires
a mating
3-conductor
grounded
type
outlet
as shown.
If
the
outlet
you
are
planning
to
use
for
this
Sander/Grinder
is
of
the
two
prong
type
DO
NOT
REMOVE
OR
ALTER
THE
GROUNDING
PRONG
iN
ANY
MANNER.
Use
an adapter
as shown
and
always
connect
the grounding
lug to a known
ground.
It is recommended
that
you
have
a qualified
electrician
replace
the
TWO
prong
outlet
with
a properly
grounded
THREE
prong outlet.
An adapter
as shown
below
is available
for connecting
plugs
to 2-prong
receptacles.
The green grounding
lug extending
from
the adapter must
be connected
to a permanent
ground
such as to a properly
grounded
outlet
box.
GROUNDI NG LUG
sURE T .Js,s
3-p ONG \
:I:
I'- :CONNECTED TOA
......... "
RECEPTACLE
NOTE:
The adapter
illustrated
is for use only
if you already
have a properly
grounded
2-prong
receptacle.
Adapter
is
not allowed
in Canada
by the Canadian
Electrical
Code.
The
use of
any
extension
cord
will
cause
some
loss of
power.
To
keep
this
to
a minimum
and
to
prevent
over-heating
and
motor
burn-out,
use the table
below
to
determine
the minimum
wire size (A,W.G.)
extension
cord,
Use
only
3 wire
extension
cords
which
have
3
prong
grounding
type
plugs
and
3-pole
receptacles
which
will
accept
the plug on the Sander/Grinder.
Extension Cord Length
Wire Size A.W,G.
Up to 100 Ft.........................
16
100-200 Ft ...........................
14
200-400 Ft ............................
10

Hide quick links: