Chapter 2 ETERNUS DX Disk Storage System Installation
2.1 Installation Specifications
Maximum
power
requirements
(*2)
Maximum heat
generation
(*2)
Maximum
amount of
exhaust air
Environmental
conditions
Vibration limit
Noise
emission (*3)
*1:
A 2U power distribution unit is composed of two 1U power distribution units.
*2:
These values are for when the controller enclosure has twenty-four disks in a 2.5" disk configuration
or when each enclosure has twelve disks in a 3.5" disk configuration.
*3:
These values are measured when a single controller enclosure is configured in an environment in
which the temperature is 23 ± 2°C.
ETERNUS DX60 S2 Disk storage system User's Guide -Site Planning-
Item
AC 100 – 120V
Controller
enclosure
AC 200 – 240V
AC 100 – 120V
Drive
enclosure
AC 200 – 240V
AC 100 – 120V
Controller
enclosure
AC 200 – 240V
AC 100 – 120V
Drive
enclosure
AC 200 – 240V
Controller enclosure
Drive enclosure
Operating
Temperature
Not operating
Shipping
Temperature gradient
Operating
Humidity
Not operating
Shipping
Humidity gradient
Maximum wet bulb temperature
Altitude above sea level
Air borne dust
Gas concentration tolerance
level
Oil vapor
Seawater (salt corrosion)
Operating
Not operating
Sound Pressure Level (LpAm)
Sound Power Level (LWAd)
27
Copyright 2012 FUJITSU LIMITED
ETERNUS DX60 S2
2.5" disk configuration
3.5" disk configuration
510W (520VA)
500W (510VA)
1,840kJ/h
1,800kJ/h
3
2.9m
/min
3
2.9m
/min
10 – 40°C
0 – 50°C
-40 – 60°C
15°C/Hr or less
20 – 80%RH
8 – 80%RH
8 – 90%RH
30%/day or less
29°C
0 – 3,000m
3
0.15mg/m
or less
Cl
: 3.4ppb or less, H
S: 7.1ppb or less
2
2
SO
: 37ppb or less, NH
: 420ppb or less
2
3
NO
: 52ppb or less, O
: 5ppb or less
2
3
HCl: 6.6ppb or less, HF: 3.6ppb or less
3
0.2mg/m
or less
If the ETERNUS DX Disk storage system is
installed on the ocean or premises within 0.5km
from the coast, necessary measures must be
taken to prevent salt corrosion.
400gal
1,000gal
43.5dB(A)
42.0dB(A)
6.0B
5.9B
440W (450VA)
430W (440VA)
370W (380VA)
370W (380VA)
1,590kJ/h
1,550kJ/h
1,340kJ/h
1,340kJ/h