Hitachi GR2000 Series Installation Manual page 309

Gigabit router
Hide thumbs Also See for GR2000 Series:
Table of Contents

Advertisement

Table 5-7 shows typical power consumption and heat dissipation figures. Each
configuration assumes the maximum configuration.
Table 5-7
Typical Power Consumption and Heat Dissipation Figures
Configuration
GR2000-2S
GR2000-4S
GR2000-6H
GR2000-10H with either redundant
or non-redundant POW(s)
GR2000-20H with either redundant 200 Vac
Input Power Condition
Voltage
Frequency
100 Vac
50/60 ±1 Hz
100 Vac
50/60 ±1 Hz
200 Vac
50/60 ±1 Hz
100 Vac
50/60 ±1 Hz
200 Vac
50/60 ±1 Hz
–48 Vdc
100 Vac
50/60 ±1 Hz
200 Vac
50/60 ±1 Hz
–48 Vdc
50/60 ±1 Hz
Power
Heat dissipat
Consumption (A)
2
3
3
12
12
12
12
8
27
14
(W)
200
260
260
1140
1140
950
1080
1350
1170
2340