  • Page 1 P3AM-5262-01ENZ0 ETERNUS LT20 S2 (LT20S2JNXU) ETERNUS LT40 S2 (LT40S2JNXU) ETERNUS LT60 S2 (LT60S2JNXU) Tape Library User's Guide -Monitoring Software Setup Procedure-...
  • Page 2: About This Product

    "FOR SAFE OPERATION" Use the product according to the instructions and information available in this manual. Keep this manual handy for further reference. Fujitsu makes every effort to prevent users and bystanders from being injured or damage to their property. Use the product according to this manual. ABOUT THIS PRODUCT This product is designed and manufactured for use in standard applications such as office work, personal devices and household appliances.
  • Page 3 To protect the LT20 S2/LT40 S2/LT60 S2 against instantaneous voltage drop, the user should preferably provide an AC uninterruptible power supply or the like for the LT20 S2/LT40 S2/LT60 S2. Copyright 2011 FUJITSU LIMITED P3AM-5262-01ENZ0...
  • Page 4: Revision History

    Revision History (1/1) Edition Date Revised location (type) (*1) Revision − − June, 2011 *1 Items in the "Revised location" column refer to the latest edition unless the item is marked with an asterisk. An asterisk indicates an item in an older edition.
  • Page 6: Preface

    Preface Thank you for your purchasing the ETERNUS LT20 S2/LT40 S2/LT60 S2 Tape Library. To ensure the proper handling of this product, read this manual, the other manuals supplied with this product, and the manuals supplied with the server and software thoroughly and carefully before using it.
  • Page 7 Preface Abbreviation In this manual, the product names are abbreviated as follows: Long title Abbreviation Microsoft® Windows® XP Professional operating system Windows XP Microsoft® Windows® XP Home Edition operating system Microsoft® Internet Explorer® Internet Explorer P3AM-5262-01ENZ0...
  • Page 8: Note On Safety

    Note on Safety Safety Precautions Read thoroughly this manual to use this product safely and correctly. Use the unit correctly according to this manual so that damage should not reach the human body and your property. Keep this Monitoring Software Setup Procedure at hand for quick reference at anytime necessary.
  • Page 9 Note on Safety Indicates that the disassembling and modification of the product is inhibited. Indicates that the user is inhibited to touch the product. Indicates a general mandatory action or warning that cannot be specifically identified. Indicates an instruction to unplug the power cord from the outlet and turn off the circuit breaker of power distribution panel.
  • Page 10: Manual Organization

    Manual Organization ETERNUS LT20 S2 1. Preface LTO Library 2. Product Description Installing, Starting Up 3. Installing the Tape Library and Maintaining 4. Operating the LTO Library (P3AM-5382) 5. Troubleshooting 6. Servicing 7. Packaging before Transportation 8. Technical Specifications 9. Recycling and Disposal 10.
  • Page 12: Table Of Contents

    Contents Contents Preface ........................i Note on Safety....................... iii Manual Organization ....................v Chapter 1 Setting up SNMP ................1-1 1.1 SNMP Function..................1-2 1.2 Notes on Setting SNMP...............1-2 1.3 SNMP Setting Procedure..............1-2 Chapter 2 Setting up Monitoring Software ............2-1 2.1 Monitoring function ................2-2 2.2 Notes on using ETERNUS SF Storage Cruiser........2-2 2.3 ETERNUS SF Storage Cruiser Setup Procedure........2-3 2.3.1 When using SAS interface ............2-3...
  • Page 13 Contents Illustrations Tables Table 1.1 SNMP setting items..............1-5 Table 4.1 Information Events List...............4-2 Table 4.2 Warning Events ................4-3 Table 4.3 Critical Events ................4-5 Table 4.4 Configuration Events ..............4-7 viii P3AM-5262-01ENZ0...
  • Page 14: Chapter 1 Setting Up Snmp

    Chapter 1 Setting up SNMP SNMP Function Notes on Setting SNMP SNMP Setting Procedure This chapter explains the settings of the simple network management protocol (SNMP) that can be used with this device and how to set up SNMP. P3AM-5262-01ENZ0...
  • Page 15: Snmp Function

    Setting up SNMP SNMP Function This device has the functions for sending SNMP traps and collecting MIB information via SNMP. If you set up our monitoring software "ETERNUS SF Storage Cruiser" in this device, you can receive SNMP traps. Notes on Setting SNMP Make the SNMP settings from the remote management.
  • Page 16 1.3 SNMP Setting Procedure 3) In the login window, select "Administrator," enter the password, and then click the "Login" button. [Initial value] User : Administrator Password: adm001 4) When you log in to the remote management, the initial window "Library Information"...
  • Page 17 Setting up SNMP 6) The "SNMP Configuration" window is displayed. Table 1.1 lists the contents of the items required for setting SNMP. Referring to Table 1.1, enter the required data for the items in the "SNMP Configuration" window. P3AM-5262-01ENZ0...
  • Page 18: Table 1.1 Snmp Setting Items

    1.3 SNMP Setting Procedure Table 1.1 SNMP setting items Item Setting Community Set the community name of SNMP. Name - Initial value: public (for this device, the setting is initial value only.) SNMP Enable Set Enabled or Disabled for the SNMP function. - If you check this, you can manage this device from other computers running the SNMP management software.
  • Page 20: Chapter 2 Setting Up Monitoring Software

    Chapter 2 Setting up Monitoring Software Monitoring function Notes on using ETERNUS SF Storage Cruiser ETERNUS SF Storage Cruiser Setup Procedure This chapter explains the settings for monitoring software "ETERNUS SF Storage Cruiser" that can be used with this device and how to set up the monitoring software.
  • Page 21: Monitoring Function

    Setting up Monitoring Software Monitoring function To set the monitoring function with this device (LT20 S2, LT40 S2 and LT60 S2), you have to set up monitoring software "ETERNUS SF Storage Cruiser" in the monitoring server. After setting ETERNUS SF Storage Cruiser, register this device (LT20 S2, LT40 S2 and LT60 S2) as a manual embedding device.
  • Page 22: Eternus Sf Storage Cruiser Setup Procedure

    2.3 ETERNUS SF Storage Cruiser Setup Procedure ETERNUS SF Storage Cruiser Setup Procedure This section explains this device registration procedures in manual embedding mode. 2.3.1 When using SAS interface 2.3.1.1 This device connected directly to the server 1) Start the Manual Embedding Window. 2) From the menu of the Manual Embedding Window, select [Operation] - [Create New Device] - [Library Device].
  • Page 23 Setting up Monitoring Software • When selecting using the icon 3) The "New Device creation" dialog box is displayed. For this device, select "Besides," and then click the "OK" button. 4) The "New Library device creation" dialog box is displayed. Select the "Embedding Information (Required)"...
  • Page 24 2.3 ETERNUS SF Storage Cruiser Setup Procedure • Embedding Information (Required) tab: P3AM-5262-01ENZ0...
  • Page 25 Setting up Monitoring Software Option tab: Enter the required information. To monitor this device, an address must be entered in "IP Address." Display Icon Setup tab Select "Tape" for the device icon. P3AM-5262-01ENZ0...
  • Page 26 2.3 ETERNUS SF Storage Cruiser Setup Procedure 5) After entering the required information, click "OK" to create the device. 6) A dialog box indicating the completion of embedding is displayed. 7) After the above dialog box appears, the created device is then displayed in the Manual Embedding Window as shown below: P3AM-5262-01ENZ0...
  • Page 27 Setting up Monitoring Software 8) Manual embedding is complete. Exit the Manual Embedding Window. The "Refresh" dialog box is then displayed. Click "OK" to update the information. 9) The LT20 is displayed in the Main View. This completes the setup of ETERNUS SF Storage Cruiser.
  • Page 28: When Using Fibre Channel Interface

    2.3 ETERNUS SF Storage Cruiser Setup Procedure 2.3.2 When using Fibre channel interface 2.3.2.1 This device connected through a fibre channel switch 1) Start the Manual Embedding Window. 2) From the menu of the Manual Embedding Window, select [Operation] - [Create New Device] - [Library Device].
  • Page 29 Setting up Monitoring Software 3) The "New Device creation" dialog box is displayed. Because this device is LT20 S2/LT40 S2/LT60 S2, select "Besides" and then click the "OK" button. 4) The "New Library device creation" dialog box is displayed. Select the "Embedding Information (Required)"...
  • Page 30 2.3 ETERNUS SF Storage Cruiser Setup Procedure 5) After entering the required information, click "OK" to create a device. 6) A dialog box indicating the completion of embedding is displayed. 7) After the above dialog box appears, the created device is then displayed in the Manual Embedding Window as shown below: P3AM-5262-01ENZ0 2-11...
  • Page 31 Setting up Monitoring Software 8) Select the Unknown FC port of the fibre channel switch to which this device is connected, and then drag and drop it onto the created LT20 S2/LT40 S2/LT60 S2. 9) The "New Storage device setup" dialog box is displayed. Select the "Embedding Information (Required)"...
  • Page 32 2.3 ETERNUS SF Storage Cruiser Setup Procedure 10) Select the "Option" tab in the "New Storage device setup" dialog box, and then set information on a drive in this device. Caution Operation failure Do not set any information in the "IP Address" and "Management Software"...
  • Page 33 Setting up Monitoring Software 11) After entering the required information, click "OK." 12) The dialog box shown below is displayed. Click "OK" and set the drive information. 13) The fibre channel switch and this device are connected by a physical line as shown in the figure below.
  • Page 34 2.3 ETERNUS SF Storage Cruiser Setup Procedure 14) Manual embedding of this device is complete. Exit the Manual Embedding Window. The "Refresh" dialog box is displayed. Click "OK" to update information. 15) This device connected to the fibre channel switch by a physical line is displayed in the Main View.
  • Page 35: 2.3.2.2 This Device Connected Directly To The Server

    Setting up Monitoring Software 2.3.2.2 This device connected directly to the server 1) Start the Manual Embedding Window. 2) From the menu of the Manual Embedding Window, select [Operation] - [Create New Device] - [Library Device]. You can also perform this step by selecting the relevant icon from the toolbar.
  • Page 36 2.3 ETERNUS SF Storage Cruiser Setup Procedure 3) The "New Device creation" dialog box is displayed. Because this device is LT20 S2/LT40 S2/LT60 S2, select "Besides" and then click the "OK" button. 4) The "New Library device creation" dialog box is displayed. Select the "Embedding Information (Required)"...
  • Page 37 Setting up Monitoring Software 5) After entering the required information, click "OK" to create a device. 6) A dialog box indicating the completion of embedding is displayed. 7) After the above dialog box appears, the created device is then displayed in the Manual Embedding Window as shown below: 2-18 P3AM-5262-01ENZ0...
  • Page 38 2.3 ETERNUS SF Storage Cruiser Setup Procedure 8) Click the Unknown FC port of the server to which this device is connected, and then drag and drop it onto the created LT20 S2/LT40 S2/LT60 S2. 9) The "New Storage device setup" dialog box is displayed. Select the "Embedding Information (Required)"...
  • Page 39 Setting up Monitoring Software 10) Select "Option" in the "New Storage device setup" dialog box, and then set information on a drive in this device. Caution Operation failure Do not set any information in the "IP Address" and "Management Software" fields. Don’t set.
  • Page 40 2.3 ETERNUS SF Storage Cruiser Setup Procedure 11) After entering the required information, click "OK." 12) The dialog box shown below is displayed. Click "OK" and then set the drive information. P3AM-5262-01ENZ0 2-21...
  • Page 41 Setting up Monitoring Software 13) The server and this device are connected by a physical line as shown in the figure below. 14) Manual embedding of this device is complete. Exit the Manual Embedding Window. The "Refresh" dialog box is then displayed. Click "OK" to update information.
  • Page 42 2.3 ETERNUS SF Storage Cruiser Setup Procedure 15) This device connected to the server by a physical line is displayed in the Main View. This completes the setup of ETERNUS SF Storage Cruiser. P3AM-5262-01ENZ0 2-23...
  • Page 44: Chapter 3 Confirming The Snmp Trap Settings

    Chapter 3 Confirming the SNMP Trap Settings Confirming the Monitoring Setting Confirming the setting by sending a test trap from the remote management Procedure for Recovery to the Normal Status After monitoring software "ETERNUS SF Storage Cruiser" is set up, the monitoring server receives SNMP traps (events) sent by this device.
  • Page 45: Confirming The Monitoring Setting

    Confirming the SNMP Trap Settings Confirming the Monitoring Setting Check whether the monitoring server normally receives SNMP traps (events) sent by this device after monitoring software "ETERNUS SF Storage Cruiser" is set up. Do this by taking the following steps in the order given: Send a test trap from this device.
  • Page 46 3.2 Confirming the setting by sending a test trap from the remote Management 6) Click the "Logoff" button. 7) The event information for the test trap is sent to ETERNUS SF Storage Cruiser on the monitoring server. Confirm that the event information is displayed in the "ETERNUS SF Storage Cruiser"...
  • Page 47: Procedure For Recovery To The Normal Status

    Confirming the SNMP Trap Settings Procedure for Recovery to the Normal Status This section explains two methods for using ETERNUS SF Storage Cruiser for recovery to the normal status. Either method is suitable. 1) Recovery from the resource management window 2) Recovery from the Manual Embedding Window 3.3.1 Procedure for recovery from the resource management...
  • Page 48: Procedure For Recovery From The Manual Embedding Window

    3.3 Procedure for Recovery to the Normal Status 3.3.2 Procedure for recovery from the Manual Embedding Window 1) Open the Manual Embedding Window of ETERNUS SF Storage Cruiser. 2) In the Manual Embedding Window, select and right-click the icon of the device.
  • Page 49 Confirming the SNMP Trap Settings 3) "Change Device Information" dialog is displayed. A choice in Device Status is 'normal', 'warning' and 'error'. 4) Select 'normal'. 5) The device icon turns green, and the device status changes to "normal." This completes the procedure for recovery to the normal status from the Manual Embedding Window.
  • Page 50: Chapter 4 Event List

    Chapter 4 Event List Event List This chapter explains the events that are reported by SNMP of this device. P3AM-5262-01ENZ0...
  • Page 51: Event List

    Event List Event List The table below lists the events reported by SNMP. Displayed character strings may be changed as a result of firmware revision. 4.1.1 Information Events Table 4.1 Information Events List Events Events Code Description Move Element 0x01 Move Element command Inventory rescan 0x02...
  • Page 52: Warring Events

    4.1 Event List 4.1.2 Warring Events Table 4.2 Warning Events (1/2) Events Events Code Description SCSI invalid opcode 0x30 SCSI invalid opcode invalid element address 0x31 invalid element address invalid field in CDB 0x32 invalid field in CDB invalid SCSI ID message 0x33 invalid SCSI ID message invalid LUN...
  • Page 53 Event List Table 4.2 Warning Events (2/2) Events Events Code Description invalid cartridge 0x60 invalid cartridge invalid upgrade Cartridge 0x61 invalid upgrade cartridge invalid cleaning cartridge 0x62 invalid cleaning cartridge cleaning tape installed 0x63 cleaning tape installed cleaning failed 0x64 cleaning failed cleaning tape expired 0x65...
  • Page 54: Critical Events

    4.1 Event List 4.1.3 Critical Events Table 4.3 Critical Events (1/2) Events Events Code Description BCR Failure 0x80 HE: bar code reader init. failed BCR Failure 0x81 HE: no response from BCR Hardware Error 0x82 HE: no response from EEPROM Robotic Error 0x83 HE: robotic controller error...
  • Page 55 Event List Table 4.3 Critical Events (2/2) Events Events Code Description Network Failure 0xC0 HE: network init Network Failure 0xC1 HE: telnet interface Network Failure 0xC2 HE: webserver Net HW Failure 0xC3 HE: EEPROM parameter Net HW Failure 0xC4 HE: cannot init LanCard Net HW Failure 0xC5 HE: write data to EEPROM fail...
  • Page 56: Configuration Events

    4.1 Event List 4.1.4 Configuration Events Table 4.4 Configuration Events Events Events Code Description Drive SCSI changed 0x41 Drive SCSI ID has changed Library SCSI changed 0x42 Library SCSI ID changed (Note) Drive Enable 0x43 Drive was enabled Drive Disable 0x44 Drive disabled Master Drive assigned...