Front Panel to SCPI Command Maps
Gate & ExtArm Key to SCPI Command Map (Cont.) — For
HP 53132A (With S/N Prefix 3646 and Above)
Time Interval
(HP 53131A and HP 53132A With S/N Prefix Below 3646)
Auto Arming:
a.
[:SENSe]:TINTerval:ARM:ESTART:LAYer2:SOURce IMMediate
[:SENSe]:TINTerval:ARM:ESTOP:LAYer2:SOURce IMMediate
b 1 . [:SENSe]:TINTerval:ARM:ESTOP[:LAYer[1]]:SOURce IMMediate
b 2 . [:SENSe]:TINTerval:ARM:ESTOP[:LAYer[1]]:SOURce TIMer
b 3 . [:SENSe]:TINTerval:ARM:ESTOP[:LAYer[1]]:SOURce INTernal2
c.
[:SENSe]:TINTerval:ARM:ESTOP[:LAYer[1]]:TIMer <numeric_value>
d.
[:SENSe]:TINTerval:ARM:ESTOP[:LAYer[1]]:ECOunt <numeric_value>
External Arming:
e.
[:SENSe]:TINTerval:ARM:ESTART:LAYer2:SOURce EXTernal
f.
[:SENSe]:TINTerval:ARM:ESTART:LAYer2:SLOPe POSitive | NEGative
g 1 . [:SENSe]:TINTerval:ARM:ESTART[:LAYer[1]]:SOURce IMMediate
g 2 . [:SENSe]:TINTerval:ARM:ESTART[:LAYer[1]]:SOURce TIMer
g 3 . [:SENSe]:TINTerval:ARM:ESTART[:LAYer[1]]:SOURce INTernal1
h. [:SENSe]:TINTerval:ARM:ESTART[:LAYer[1]]:TIMer <numeric_value>
[S]
i.
[:SENSe]:TINTerval:ARM:ESTART[:LAYer[1]]: ECOunt
<numeric_value>
j 1 . [:SENSe]:TINTerval:ARM:EST OP:LAYer2:SOURce IMMediate
j 2 . [:SENSe]:TINTerval:ARM:EST OP:LAYer2:SOURce EXTernal
k.
[:SENSe]:TINTerval:ARM:EST OP:LAYer2:SLOPe POSitive I NEGative
m 1 . [:SENSe]:TINTerval:ARM:ESTOP[:LAYer[1]]:SOURce IMMediate
m 2 . [:SENSe]:TINTerval:ARM:ESTOP[:LAYer[1]]:SOURce TIMer
m 3 . [:SENSe]:TINTerval:ARM:ESTOP[:LAYer[1]]:SOURce INTernal2
n.
[:SENSe]:TINTerval:ARM:ESTOP[:LAYer[1]]:TIMer <numeric_value>
[S]
o.
[:SENSe]:TINTerval:ARM:ESTOP[:LAYer[1]]:ECOunt <numeric_value>
Figure 2-4. Gate & ExtArm Key to SCPI Command Map (Part 6 of 6)