eMonitor/Alarm Notification
Strata CIX Network eMonitor

Step 8: Set up vbAlarm Notification

Alarm Notification Setup Screen
This screen sends commands to add/remove alarm traps and enables/disables alarm notification.
Note
Table 5
Alarm Notification Setup Screen Fields
F
IELD
CIX Name
CIX IP Address
CIX Trap Destination
Setup
Alarm
Periodical Summary
5-12
If the CIX is behind a NAT router and eMonitor is not on the same LAN as CIX, eMonitor
cannot administer CIX Alarm programs. eMonitor can only monitor (receive) Alarm data
from the CIX.
D
ESCRIPTION
Display only. Name of CIX stored in the eMonitor Database.
Note Equipment marked as Monitor only mode does not display here.
Display only. IP Address of the CIX system. For example: 192.168.254.253.
Currently On/Off List — Indicates the eMonitor is on the target CIX Trap Destination list
or not. Current On List means that eMonitor's IP is registered in target CIX Trap
Destination List. Currently Off means that eMonitor's IP is not in the target CIX Trap
Destination List. If the eMonitor is not on the list, the CIX alarm will not be displayed on
this screen.
If this field displays an "X," it means there is a problem in connecting to the target CIX.
Currently All On/Off — Turns On/Off the Alarm Notification of a CIX.
Currently On/Off — Turns On/Off the Current Alarm Summary Notification of a CIX.
Strata CTX Application Implementation Vol 3
10/07