(f)
Image control registers #5 and #6
#5
7
6
5
4
0
0
0
0
*1 Registers #5 and #6 must be sent consecutively. Registers #5, #6, #7, and #8
must be sent consecutively for different vertical/horizontal magnification.
*2 When the vertical/horizontal zooming specification is set to ™0∫, the horizontal
and vertical magnification is indicated. When this specification is set to ™1∫,
vertical magnification is specified at bit 0 of the register #5 and at all bits of the
register #6.
X©0864π is set when the power is turned on or when the initial status is specified.
Example
How to calculate the output resolution :
f
Control register #1 is X©0Bπ (200 dpi)
f
Image control register #5 and #6 are X©0819π (25%)
Output resolution = 200 dpi ¥ 0.25 = 50 dpi
6 $ 28
(
LSB)
3
2
1
0
7
6
1
0
Magnification/vertical magnification (when
each direction zooming is valid)
000011001
110010000
Vertical/horizontal zooming specification (*2)
0: Same magnification for both direction
1: Different magnification for each
50FH5037E>02
(
#6
5
4
3
2
1
25%
to
to
400%
direction
LSB)
0
(*1)