Hitachi CB6YI - 10 Inch Tilting Head Bandsaw Instruction Manual page 14

10″ band saw
Hide thumbs Also See for CB6YI - 10 Inch Tilting Head Bandsaw:
Table of Contents

Advertisement

Available languages

Available languages

English
UPPER BLADE GUIDES AND BLADE SUPPORT BEARING
(Fig. K, L)
WARNING
The blade guard has been removed for clarity of
illustration. To avoid injury never operate the band
saw without all guards in place and in working order.
To avoid injury, turn the switch OFF and disconnect
the saw from the power source before making any
adjustments. NEVER make adjustments with the
machine running.
NOTE: Make sure the blade is tensioned and tracking
properly. Adjust the blade guides and support bearing after
each blade tension and tracking adjustment. When the upper
blade guides and support bearings are adjusted, the lower
guides and bearings should also be adjusted.
Blade guides (Fig. K)
1.
Make sure the blade is tensioned and tracking properly.
2.
Loosen the front hex socket screws (1) with a hex
wrench.
3.
Move the guides (2) as close to the blade (3) as possible
without pinching it.
4.
Using a feeler gauge, make sure the space between
each guide and blade measures 0.02" (the thickness of
a dollar bill).
5.
Tighten the hex socket screws.
Fig. K
3
2
Support bearing (Fig. L)
6.
Loosen the bearing hex nut (4).
7.
Move the support bearing shaft (5) in or out, until the
bearing (6) is 1/64" behind the blade.
8.
Tighten the hex nut (4).
NOTE: The blade support bearing prevents the blade from
moving back too far and damaging the saw teeth setting.
2
1
3
– 14 –
Fig. L
6
LOWER BLADE GUIDES AND SUPPORT BEARING
(Fig. M, N)
WARNING
To avoid injury, turn the switch OFF and disconnect the saw
from the power source before making any adjustments.
NEVER make adjustments with the machine running.
NOTE: Make sure the blade is tensioned and tracking
properly.
The lower blade guides and support bearings should always
be adjusted after the blade is tensioned, the tracking is
adjusted, and the upper blade guides and upper support
bearings are properly adjusted.
Blade guides (Fig. M)
1.
Loosen both front hex socket screws (1) with a hex
wrench.
2.
Move the guides (2) as close to the sides of the blade (3)
as possible without pinching it.
3.
Using the feeler gauge, measure the spaces between
the guide and the blade. Adjust to 0.02".
4.
Tighten the hex screws.
Fig. M
3
1
6
5
4
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cb6y

Table of Contents