Fuse
Power
Cord
Q-spring
Hinge Pin
Back
panel
Inlet valve ass'y
Fuse holder
B.P Sensor
Hinge Pin
2) Disassembly of Back Panel, Power
Cord, Inlet Valve & BP Sensor
Remove two back panel fixing screws in the back
side.
Disassemble the back panel.
Disconnect two connectors and disassemble the
power cord.
Remove a valve fixing screw & disconnect the
leads form the inlet valve.
Remove the inlet valve.
Disconnect the leads & the pressure tube from the
BP sensor.
Remove the BP sensor.
Fuse is located in the Fuse holder.
For fuse replacement use the following rated fuse
* Rating of fuse
- 250V 6A fusing type for 220-240V product
- 125V 12A fusing type for 100-127V product
3) Disassembly of Lid Assembly, Top
Cover, Tub Cover, Pulsator & Inner Tub
Remove Q-spring & two hinge pins then
disassemble the lid assembly
Remove two top cover fixing screws in the rear
then disassemble the top cover.
Remove tub cover fixing screws then disassemble
the tub cover.
Remove the pulsator fixing screw then disassemble
the pulsator.
Remove the hub fixing nut by a special tool.
Disassemble the inner tub.