Bosch Conettix D6600 Installation And Operation Manual page 69

Communications receiver/gateway
Hide thumbs Also See for Conettix D6600:
Table of Contents

Advertisement

Conettix Communications Receiver/
Gateway
Notice!
i
If the default value displayed in your Telnet window does not match the value listed in any of
the steps below, type the correct value and press Enter.
1.
2.
3.
4.
5.
6.
7.
8.
9.
If you want to enable encryption, continue with the next step, or skip ahead to the last step.
Notice!
i
If encryption is enabled on the D6100i, it must be enabled on all field devices.
1.
2.
3.
4.
5.
Bosch Security Systems, Inc.
At the Baud Rate prompt, press Enter to accept the default (38400).
At the I/F Mode prompt, press Enter to accept the default (4C).
At the Flow prompt, press Enter to accept the default (00).
Type a unique Port Number for the LAN to which the D6100i is connected and press
Enter.
At the ConnectMode prompt, press Enter to accept the default (CC).
At the Datagram Type prompt, type 00 or 02 and press Enter.
At the IP addr prompt, type the remote IP address used for the D6600 to which the
C900V2 reports and press Enter.
Enter the remote IP address using 000.000.000.000 format.
Type the Port Number for the D6600 and press Enter.
From the Change Setup menu, type 6 and press Enter.
This information appears.
At the Disable SNMP prompt, press Enter to accept the default (N).
At the SNMP Community Name prompt, press Enter to accept the default (blank).
At the Disable Telnet Setup prompt, press Enter to accept the default (N).
At the Disable Port 77FEh prompt, press Enter to accept the default (N).
Installation and Operation Guide
Network Communications | en
2012.11 | 08 | 4998122704
69