Side access panel solenoid lock
The side access panel solenoid lock provides a method to lock the side access panel by means of a
local or remote signal-controlled solenoid.
This section describes how to remove and install the side access panel solenoid lock.
Removing the side access panel solenoid lock
To remove the side access panel solenoid lock:
1.
Power down the workstation (see
2.
Disconnect power from the workstation (see
3.
Remove the side access panel (see
4.
Disconnect the side access panel solenoid lock cable from the system board (1).
5.
Remove the two screws that fasten the solenoid lock to the chassis (2), as shown in the following
figure.
6.
Pull the solenoid lock assembly inward and then up (3) to remove the assembly from the chassis.
Figure 5-8
Installing the side access panel solenoid lock
Reverse the above steps to install the side access panel solenoid lock. This involves connecting the
solenoid lock cable to the system board and fastening the solenoid lock to the chassis.
82
Chapter 5 Replacing components
Predisassembly procedures on page
Removing the side access panel on page
Removing the side access panel solenoid lock
Predisassembly procedures on page
75).
75).
78).
ENWW