Rxlevel [-20 To +6]; Rxtot [None, 1-1440]; Scd [0-255]; Ser - GE MDS 4710A Technical Manual

Mds 4710/9710 series 400 mhz and 900 mhz remote data transceivers
Table of Contents

Advertisement

RX Audio Output
Level
Loss of RX Data
Alarm Time
Soft-Carrier Dekey
Radio's Serial
Number
Show Power
Settings
RX Signal-to-Noise
Ratio
30
RXLEVEL [–20 to +6]
The
RXLEVEL command
present on Pin 11 of the
function in
MODEM NONE

RXTOT [NONE, 1-1440]

The
command selects or displays the receive time-out timer value
RXTOT
in minutes. This timer triggers an alarm (event 12) if data is not detected
within the specified time.
Entering the
command without a parameter displays the timer
RXTOT
value in minutes. Entering the
ranging from 0 to 255 resets the timer in minutes. Entering the
command with the parameter

SCD [0-255]

This command displays or changes the soft-carrier dekey delay in milli-
seconds.
This timer specifies how long to wait after the removal of the keying
signal before actually releasing the transmitter. A value of 0 ms unkeys
the transmitter immediately after the removal of the keying signal.

SER

This command displays the radio's serial number as recorded at the fac-
tory.

SHOW [DC, PORT, PWR]

The
command displays different types of information based on
SHOW
the command variables. The different parameters are:
—Display DC input/output voltages
DC
—Display the connector port (RJ-11 or DB-25) that is active
PORT
for diagnostics and control.
—Display RF power output
PWR

SNR

This command continuously displays the signal-to-noise (SNR) ratio of
the received signal expressed in dB, until you press the
used in this guide, the SNR measurement is based upon the signal level
following equalization for received frames.
The SNR is an indication of the received signal quality. The SNR indi-
cation ranges from 10 dB to 33 dB. A value of 10 dB represents a very
poor signal. A value of 24 dB represents a very good signal.
MDS 4710/9710 Technical Manual
selects or displays the receive output level
DATA INTERFACE
's DB-25 connector. Use this
mode with analog audio.
command with a parameter
RXTOT
disables the timer.
NONE
RXTOT
key. As
ENTER
MDS 05-3305A01, Rev. E

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mds 4710m

Table of Contents