Fujitsu D2863 Tehnical Manual
Fujitsu D2863 Tehnical Manual

Fujitsu D2863 Tehnical Manual

System board for primergy rx100 s6

Advertisement

Technical Manual - English
System Board D2863
for PRIMERGY RX100 S6
Technical Manual
Edition February 2011

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu D2863

  • Page 1 Technical Manual - English System Board D2863 for PRIMERGY RX100 S6 Technical Manual Edition February 2011...
  • Page 2 All hardware and software names used are trademarks of their respective manufacturers. Ê The contents of this manual may be revised without prior notice. Fujitsu assumes no liability for damages to third party copyrights or other rights arising from Ê the use of any information in this manual.
  • Page 3 It has not been designed or manufactured for uses which demand an extremely high level of safety and carry a direct and serious risk to life or body if such safety cannot be ensured. Technical Manual D2863 (RX100 S6)
  • Page 4 (hereafter, "high safety use"). Customers should not use this product for high safety use unless measures are in place for ensuring the level of safety demanded of such use. Please consult the sales staff of Fujitsu if intending to use this product for high safety use.
  • Page 5 Only for the Japanese market: Although described in this manual, some sections do not apply to the Japanese market. These options and routines include: – USB Flash Module (UFM) – CSS (Customer Self Service) – Replacing the lithium battery Technical Manual D2863 (RX100 S6)
  • Page 6 Technical Manual D2863 (RX100 S6)
  • Page 7: Table Of Contents

    Jumper ......33 Replacing the lithium battery ....35 Technical Manual D2863 (RX100 S6)
  • Page 8 Contents Technical Manual D2863 (RX100 S6)
  • Page 9: Introduction

    DVDs (see Installation DVD of ServerView Suite - ServerView Software Products). You will find further information about the BIOS setup in the “D2863 BIOS Setup Utility for RX100 S6” manual. PRIMERGY manuals are available in PDF format on the PRIMERGY ServerView Suite DVD 2.
  • Page 10 Introduction Technical Manual D2863 (RX100 S6)
  • Page 11: Important Information

    Information on which system expansions are approved for installation can be obtained from our customer service center or your sales outlet. The warranty expires if the device is damaged during the installation or replacement of system expansions. Technical Manual D2863 (RX100 S6)
  • Page 12 (this information doesn’t apply to the Japanese market). It is essential to observe the instructions in the chapter "Replacing the lithium battery". Technical Manual D2863 (RX100 S6)
  • Page 13 Do not touch any connectors or conduction paths on an ESD. Place all the components on a pad which is free of electrostatic charge. For a detailed description of how to handle ESD components, see the relevant European or international standards (EN 61340-5-1, ANSI/ESD S20.20). Technical Manual D2863 (RX100 S6)
  • Page 14: Ce Certificate Of Conformity

    The board complies with the requirements of the EC directives 2004/108/EC regarding “Electromagnetic Compatibility” and 2006/95/EC “Low Voltage Directive”. This is indicated by the CE marking (CE = Communauté Européenne). Compliance was tested in a typical PRIMERGY configuration. Technical Manual D2863 (RX100 S6)
  • Page 15: Environmental Protection

    Environmental protection Environmental protection Environmentally-friendly product design and development This product has been designed in accordance with the Fujitsu standard for "environmentally friendly product design and development". This means that key factors such as durability, selection and labeling of materials, emissions, packaging, ease of dismantling and recycling have been taken into account.
  • Page 16 Details regarding the return and recycling of devices and consumables within Europe can also be found in the "Returning used devices" manual, via your local Fujitsu branch or from our recycling center in Paderborn: Fujitsu Technology Solutions Recycling Center D-33106 Paderborn Tel.
  • Page 17: Features

    – 1x backplane power connector 8 pin – 1x connector for fans and ODD – 1x front panel connector – 1x front USB connector (for the two USB connectors on the front side) – 1x connector for optional Front VGA module Technical Manual D2863 (RX100 S6)
  • Page 18 – Phoenix SecureCore – SMBIOS 2.5 (DMI) – Server Hardware Design Guide – WfM 2.0 – ACPI 2.0 support – USB keyboard/mouse – boot possible from: – CD-ROM/DVD (SATA) – hard disk (SATA, SAS, USB) – LAN Technical Manual D2863 (RX100 S6)
  • Page 19 TPM or the system board is faulty you will not be able to access your data. – If a failure occurs, please inform your service about the TPM activation before it takes any action, and be prepared to provide them with your backup copies of the TPM content. Technical Manual D2863 (RX100 S6)
  • Page 20: Main Memory

    – The maximum performance can be achieved in a symmetric dual-channel configuration. Therefore both channels have to be populated with the same amount of memory. The DRAM device technology (1Gbit / 2Gbit) may vary from one channel to the other. Technical Manual D2863 (RX100 S6)
  • Page 21 RDIMM memory modules are only supported by Intel Quad-Core processors (Xeon 3400 series). Total memory size: up to 32 GB Configuration per Max. speed DIMM-2 DIMM-1 channel DDR3-1333 empty SR/DR DDR3-1066 empty DDR3-1333 SR/DR SR/DR DDR3-800 Technical Manual D2863 (RX100 S6)
  • Page 22 Under Pentium G6950 and Celeron G1101, the clock rate will be limited to 1066 MHz. Total memory size: up to 16 GB Configuration per Max. speed DIMM-2 DIMM-1 channel DDR3-1333 empty SR/DR DDR3-1333 SR/DR SR/DR Technical Manual D2863 (RX100 S6)
  • Page 23: Pci Slots

    175 mm one slot Slot for riser card low-profile PCIe x8 slot, Express riser card offers maximum length 170 mm x8 and x4 two slots PCIe x4 slot (mech. x8), only for modular RAID Technical Manual D2863 (RX100 S6)
  • Page 24 Interrupt signal iRMC S2 graphic PCI-INTA Intel 82574 PCI-INTA Intel 82578 PCI-INTA Slot 3 PCIe x4 PCI_INTA, PCI_INTB, PCI_INTC, PCI_INTD Slot 2 PCIe x8 PCI_INTA, PCI_INTB, PCI_INTC, PCI_INTD Slot 1 PCIe x8 PCI_INTA, PCI_INTB, PCI_INTC, PCI_INTD Technical Manual D2863 (RX100 S6)
  • Page 25: Screen Resolution

    C temperature sensor. Fan monitoring The power supply unit and system fans are monitored. Fans that are no longer available, blocked or stuck fans are detected. Technical Manual D2863 (RX100 S6)
  • Page 26 BIOS Setup, iRMC S2’s Web interface or via the ServerView Operations Manager. PRIMERGY Local Diagnostic LEDs Optical signaling through the LEDs on the system board identifies defective modules and components (CSS functionality) as well as gaining information on the PDA (Prefailure Detection and Analysis). Technical Manual D2863 (RX100 S6)
  • Page 27: Connectors And Indicators

    USB1/2 indicate button LAN1 / DIMM2A USB3/4 DIMM1A Fan2 DIMM2B VGA/ COM1 DIMM1B Front SMBus LSP Riser card (x8 and x4) &USB Internal Power fans&ODD Fan1 Figure 5: Internal connectors of the system board D2863 Technical Manual D2863 (RX100 S6)
  • Page 28 C signaling connector for LocalView Service Panel Power supply connector for system fans and ODD Connector for USB Flash Module (UFM) 5x SATA connector Connector for optional Front VGA module Connector for TPM needs optional cable Technical Manual D2863 (RX100 S6)
  • Page 29 LEDs are only visible, if the cover of the server has been opened. If the server has been powered off (power-plugs must be disconnected) it is possible to indicate the faulty component by pressing the CSS indicate button. Technical Manual D2863 (RX100 S6)
  • Page 30 G - PCI card no failure orange on PCI card failure (PCI card installed on riser card) H - iRMC iRMC S2 inactive green flashing iRMC S2 okay Technical Manual D2863 (RX100 S6)
  • Page 31: Connector Panel

    1 Gbit/s. The LAN controllers also support WOL functionality by means of Magic Packet™. It is also possible to start a system via a LAN without a separate boot hard disk drive. PXE is supported here. Technical Manual D2863 (RX100 S6)
  • Page 32 Remains dark in the event of a LAN transfer rate of 10 Mbit/s. Steady green signal when a LAN connection exists. link/transfer Remains dark when no LAN connection exists. (system LAN/ shared LAN) Flashes green when LAN transfer takes place. Technical Manual D2863 (RX100 S6)
  • Page 33: Jumper

    Default: Figure 9: Jumper Jumper Description Setting Clear RTC 1-2 normal operation (default) 2-3 clear RTC_RST register Password open: normal operation (default) SKIP short: skip password BIOS 1-2 normal operation (default) recovery 2-3 recovery mode Technical Manual D2863 (RX100 S6)
  • Page 34 Connectors and indicators Technical Manual D2863 (RX100 S6)
  • Page 35: Replacing The Lithium Battery

    Ê Press the locking spring into direction of the arrow (1), so that the lithium battery jumps out of its socket. Ê Remove the battery (2). Ê Insert a new lithium battery of the same type into the socket (3) and (4). Technical Manual D2863 (RX100 S6)
  • Page 36 Replacing the lithium battery Technical Manual D2863 (RX100 S6)

Table of Contents