Fujitsu D2870 Tehnical Manual
Fujitsu D2870 Tehnical Manual

Fujitsu D2870 Tehnical Manual

For primergy rx600 s5

Advertisement

Quick Links

Technical Manual - English
System Board D2870
for PRIMERGY RX600 S5
Technical Manual
April 2010

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu D2870

  • Page 1 Technical Manual - English System Board D2870 for PRIMERGY RX600 S5 Technical Manual April 2010...
  • Page 2 – The contents of this manual may be revised without prior notice. – Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual. – No part of this manual may be reproduced in any form without the prior written permission of Fujitsu.
  • Page 3 It has not been designed or manufactured for uses which demand an extremely high level of safety and carry a direct and serious risk to life or body if such safety cannot be ensured. Technical Manual D2870 (RX600 S5)
  • Page 4 (hereafter, "high safety use"). Customers should not use this product for high safety use unless measures are in place for ensuring the level of safety demanded of such use. Please consult the sales staff of Fujitsu if intending to use this product for high safety use.
  • Page 5 Only for the Japanese market: Although described in this manual, some sections do not apply to the Japanese market. These options and routines include: – CSS (Customer Self Service) – USB Flash Module (UFM) – Replacing the lithium battery Technical Manual D2870 (RX600 S5)
  • Page 6 Technical Manual D2870 (RX600 S5)
  • Page 7: Table Of Contents

    Connectors and indicators on the I/O riser board ..51 Replacing the lithium battery ....55 Technical Manual D2870 (RX600 S5)
  • Page 8 Contents Technical Manual D2870 (RX600 S5)
  • Page 9: Introduction

    DVDs (see Installation DVD of ServerView Suite - ServerView Software Products). You will find further information about the BIOS setup in the "D2870 BIOS Setup Utility for RX600 S5" manual. PRIMERGY manuals are available in PDF format on the ServerView Suite DVD 2.
  • Page 10 Notational conventions Introduction Technical Manual D2870 (RX600 S5)
  • Page 11: Important Information

    Information on which system expansions are approved for installation can be obtained from our customer service center or your sales outlet. The warranty expires if the device is damaged during the installation or replacement of system expansions. Technical Manual D2870 (RX600 S5)
  • Page 12 (this information doesn’t apply to the Japanese market). It is essential to observe the instructions in the chapter "Replacing the lithium battery". Technical Manual D2870 (RX600 S5)
  • Page 13 Do not touch any connectors or conduction paths on an ESD. Place all the components on a pad which is free of electrostatic charge. For a detailed description of how to handle ESD components, see the relevant European or international standards (EN 61340-5-1, ANSI/ESD S20.20). Technical Manual D2870 (RX600 S5)
  • Page 14: Ce Certificate Of Conformity

    The board complies with the requirements of the EC directives 2004/108/EC regarding “Electromagnetic Compatibility” and 2006/95/EC “Low Voltage Directive”. This is indicated by the CE marking (CE = Communauté Européenne). Compliance was tested in a typical PRIMERGY configuration. Technical Manual D2870 (RX600 S5)
  • Page 15: Environmental Protection

    Environmental protection Environmental protection Environmentally-friendly product design and development This product has been designed in accordance with the Fujitsu standard for "environmentally friendly product design and development". This means that key factors such as durability, selection and labeling of materials, emissions, packaging, ease of dismantling and recycling have been taken into account.
  • Page 16 Details regarding the return and recycling of devices and consumables within Europe can also be found in the "Returning used devices" manual, via your local Fujitsu branch or from our recycling center in Paderborn: Fujitsu Technology Solutions Recycling Center D-33106 Paderborn Tel.
  • Page 17: Features

    – Intel Southbridge ICH10R – Intel Boxboro I/O Hub – Intel IOP321 I/O processor Internal connectors – 2x USB 2.0 connector – 6x SATA connector – Trusted Platform Module (TPM) (Option) – 2x USB Flash Module (UFM) (Option) Technical Manual D2870 (RX600 S5)
  • Page 18 – DDR2 16-bit 667MHz memory – Chassis intrusion logic – PWM Control and Fan Tach Monitor – Voltage Level Monitor and Temperature Monitor – Real-Time Clock (RTC) – Two Watchdog Timers – System and Clock Control Technical Manual D2870 (RX600 S5)
  • Page 19 – Online update tools for main Windows and Linux versions – Local and remote update via ServerView Update Manager – SMBIOS V2.4 – Remote PXE boot support – Remote iSCSI boot support Environmental protection Battery in holder for recycling Technical Manual D2870 (RX600 S5)
  • Page 20 – You must also create a backup of the TPM content. To do this, follow the third party manufacturer's instructions. Without this backup, if the TPM or the system board is faulty you will not be able to access your data. Technical Manual D2870 (RX600 S5)
  • Page 21 Features Overview – If a failure occurs, please inform your service about the TPM activation before it takes any action, and be prepared to provide them with your backup copies of the TPM content. Technical Manual D2870 (RX600 S5)
  • Page 22: Main Memory

    The following figure shows the DIMM slot assignment of the memory riser board. Figure 2: DIMM slot assignment of memory riser board Installing and removing memory boards and DIMMs is described in the operating manual for your server. Technical Manual D2870 (RX600 S5)
  • Page 23 Each BOB controls two memory channels (e.g. A, B or C,D). For performance reasons two channels of different BOBs are used in parallel to access the DIMMs. The DIMMS that are locked together this way as pairs are called ’lockstep pairs’. Technical Manual D2870 (RX600 S5)
  • Page 24: Fitting Rules

    3. Continue with DIMM slots 2B and 2D. 4. Finally fill DIMM slots 2A and 2C. The fitting rules are also illustrated on the sticker on every memory board: Figure 4: Sticker with graphical fitting instructions on every memory board Technical Manual D2870 (RX600 S5)
  • Page 25: Memory Configuration Modes

    – Mirroring mode – Hemisphere mode After installing the DIMMs the necessary specific settings have to be done within the BIOS of the server. See the "D2870 BIOS Setup Utility for PRIMERGY RX600 S5" manual for detailed information. Spare mode In spare mode, one pair of DIMMs will be spare for the other pairs.
  • Page 26 (must be installed in slot #5). Figure 6: Performance optimized configuration for 2 CPUs and 2 memory boards For one upgrade step, 4 DIMMs have to be added (see next page): Technical Manual D2870 (RX600 S5)
  • Page 27 Figure 7: First Upgrade in Spare Mode for 2 CPUs and 2 memory boards For the next upgrade step, again 4 DIMMs have to be added: Figure 8: Second (maximum) upgrade in Spare Mode for 2 CPUs and 2 memory boards Technical Manual D2870 (RX600 S5)
  • Page 28 This type is only possible with 4 CPUs and requires 2 memory boards per CPU. The data are distributed over the Mboxes of four CPUs (see figure 11 on page 31). Therefore, this type is called "Inter Socket Interleaving". Technical Manual D2870 (RX600 S5)
  • Page 29 Figure 9: Upgrade configuration for 2 CPUs and 2 memory boards The same upgrade rules have to be applied for 2 CPUs and 4 memory boards, for 3 CPUs and 6 memory boards and for 4 CPUs and 8 memory boards. Technical Manual D2870 (RX600 S5)
  • Page 30 For one upgrade step, minimum 8 DIMMs (one color) have to be added. Figure 10: Upgrade configuration for 2 CPUs and 4 memory boards The same upgrade rules have to be applied for configurations with 4 CPUs. Technical Manual D2870 (RX600 S5)
  • Page 31 8-way interleaving mode (Inter Socket) with 4 CPUs and 8 memory boards For one upgrade step, minimum 16 DIMMs (one color) have to be added. Figure 11: Upgrade configuration for 4 CPUs and 8 memory boards This mode is only possible with 4 CPUs. Technical Manual D2870 (RX600 S5)
  • Page 32 14 on page 35). Intersocket mirroring is only possible with 4 CPUs, not with 2 or 3 CPUs. This mode requires 2 memory boards per CPU (8 total). All DIMMS must be identical (same capacity and technology)! Technical Manual D2870 (RX600 S5)
  • Page 33 Main memory Intrasocket Mirroring with 2 CPUs and 2 Memory Boards For one upgrade step, minimum 4 DIMMs (one color) have to be added. Figure 12: Upgrade configuration for 2 CPUs and 2 memory boards Technical Manual D2870 (RX600 S5)
  • Page 34 For one upgrade step, minimum 8 DIMMs (one color) have to be added. Figure 13: Upgrade configuration for 2 CPUs and 4 memory boards The same upgrade rules have to be applied for configurations with 3 or 4 CPUs. Technical Manual D2870 (RX600 S5)
  • Page 35 Main memory Intersocket Mirroring with 4 CPUs and 8 Memory Boards For one upgrade step, minimum 16 DIMMs (one color) have to be added. Figure 14: Upgrade configuration for 4 CPUs and 8 memory boards Technical Manual D2870 (RX600 S5)
  • Page 36 4, 8, 16, 32, 64 or 128 GB. The configuration of the memory boards per CPU must be the same. Hemisphere Mode with 2 CPUs and 2 Memory Boards Figure 15: Minimum configuration for 2 CPUs and 2 memory boards Technical Manual D2870 (RX600 S5)
  • Page 37 1 is equipped with 16 DIMMs after the first upgrade step, channel 2 also has to be equipped with 16 DIMMs. The same upgrade rules have to be applied for configurations with 3 and 4 CPUs. Technical Manual D2870 (RX600 S5)
  • Page 38: Memory Board Configuration Table

    (Lock- boards (2-way) socket) step) 3-way configuration Memory Mode CPU 1 CPU 2 CPU 3 CPU 4 No. of None Spare Inter- Mirror Memory Board Slot No. Mem. leaving (Intra (Lock- boards (2-way) socket) step) Technical Manual D2870 (RX600 S5)
  • Page 39 Features Main memory 4-way configuration Memory Mode CPU 1 CPU 2 CPU 3 CPU 4 No. of None Spare Inter- Mirror Memory Board Slot No. Mem. leaving (Intra (Lock- boards (2-way) socket step) Technical Manual D2870 (RX600 S5)
  • Page 40: Pcie Slots

    PCIe slots Features PCIe slots A B C D E F G H Figure 17: PCIe slots on system board D2870 Pos. PCIe slot Description Hot-plug Slot 10 PCI Express 1.0 (x4), 1/2 length, x8 connector Slot 9 PCI Express 1.0 (x4), 1/2 length, x8 connector Slot 8 PCI Express 2.0 (x4), 3/4 length, x8 connector...
  • Page 41 4 - 9 CPU 3 must be installed to support PCI slots 4 - 9 7 & 8 4 - 9 Legacy I/O devices i.e. video cards are only supported on slots #1, 2, 3, or 10 Technical Manual D2870 (RX600 S5)
  • Page 42: Screen Resolutions

    The fans are monitored. Fans that are blocked, sluggish or no longer available are detected. Fan control The fans are regulated according to temperature. Maximum speed will only be achieved when switching the server on and in case of a fan test. Technical Manual D2870 (RX600 S5)
  • Page 43 All monitored events of the system board are signalized via the Global Error LED or CSS LED and recorded in the System Event Log. They could be retrieved in the BIOS Setup, iRMC S2’s Web interface or via the ServerView Operations Manager. Technical Manual D2870 (RX600 S5)
  • Page 44: Connectors, Jumpers And Indicators

    Connectors, jumpers and indicators Features Connectors, jumpers and indicators 3.6.1 Onboard connectors Figure 18: Connectors on system board D2870 Pos. Connector Pos. Connector PCIe slots (# see figure) I/O riser slot Technical Manual D2870 (RX600 S5)
  • Page 45 Processor sockets (# see Signal connectors to Front figure) Panel Fan Board Power connectors to Power Signal connector to Power Distribution Board Distribution Board Power connector to Power Memory board slots (# see Distribution Board figure) Technical Manual D2870 (RX600 S5)
  • Page 46: Onboard Jumpers

    Connectors, jumpers and indicators Features 3.6.2 Onboard jumpers Figure 19: Position of the jumpers on system board D2870 Pos. Jumper Clear CMOS (J5C2) Password Disable/Clear (J5C3) Reserved (J5C1) BIOS Recovery (J6D1) Technical Manual D2870 (RX600 S5)
  • Page 47 Settings of Jumper "Clear CMOS" (J5C2) Clear CMOS Normal (Default) Settings of Jumper "Password Disable/Clear" (J5C3) Disable/Clear Protect (Default) Settings of the reserved Jumper (J5C1) Default setting Settings of Jumper "BIOS Recovery" (J6D1) Recover Normal (Default) Technical Manual D2870 (RX600 S5)
  • Page 48: Onboard Indicators

    Connectors, jumpers and indicators Features 3.6.3 Onboard indicators Figure 20: Indicators and indicate CSS button on system board D2870 The positions in the figure have the following meaning: Pos. Indicator Hot swap status LEDs for PCIe slot 7 Hot swap status LEDs for PCIe slot 6...
  • Page 49 The LED F is visible from outside on the rear of the server. All the other LEDs are only visible after the cover has been removed. If the server has been powered off (power-plugs must be disconnected) it is possible to indicate the faulty component by pressing the indicate CSS button. Technical Manual D2870 (RX600 S5)
  • Page 50: External Connectors And Indicators

    Connectors, jumpers and indicators Features 3.6.4 External connectors and indicators Figure 21: External connectors and indicators on system board D2870 Pos. Indicator System ID LED System ID button 2x USB connector Technical Manual D2870 (RX600 S5)
  • Page 51: Connectors And Indicators On The I/O Riser Board

    (system LAN) and an ARM9 controller (management LAN). These LAN controllers support transmission rates of 10 Mbit/s, 100 Mbit/s and 1 Gbit/s (only system LAN). They also support WoL functionality by means of Magic Packet™. Technical Manual D2870 (RX600 S5)
  • Page 52 Steady yellow signal in the event of a LAN transfer (system LAN) rate of 1 Gbit/s. Steady green signal in the event of a LAN transfer rate of 100 Mbit/s. Remains dark in the event of a LAN transfer rate of 10 Mbit/s. Technical Manual D2870 (RX600 S5)
  • Page 53 Flashes green when LAN transfer takes place. LAN speed Steady green signal in the event of a LAN transfer (management rate of 100 Mbit/s. LAN) Remains dark in the event of a LAN transfer rate of 10 Mbit/s. Technical Manual D2870 (RX600 S5)
  • Page 54 Connectors, jumpers and indicators Features Technical Manual D2870 (RX600 S5)
  • Page 55: Replacing The Lithium Battery

    Ê Take an identical lithium battery, press the metal clip in the direction of the arrow (3), and insert the lithium battery into the holder (4). Ê Dispose of the waste battery as described above. Technical Manual D2870 (RX600 S5)
  • Page 56 Replacing the lithium battery Technical Manual D2870 (RX600 S5)