Fujitsu D2952 Technical Manual

For bx924 s2

Advertisement

Quick Links

Technical Manual - English
System Board D2952
for BX924 S2
Technical Manual
Edition May 2011

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu D2952

  • Page 1 Technical Manual - English System Board D2952 for BX924 S2 Technical Manual Edition May 2011...
  • Page 2 – The contents of this manual may be revised without prior notice. – Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual. – No part of this manual may be reproduced in any without the prior written permission of Fujitsu.
  • Page 3 It has not been designed or manufactured for uses which demand an extremely high level of safety and carry a direct and serious risk to life or body if such safety cannot be ensured. Technical Manual D2952 (BX924 S2)
  • Page 4 (hereafter, "high safety use"). Customers should not use this product for high safety use unless measures are in place for ensuring the level of safety demanded of such use. Please consult the sales staff of Fujitsu if intending to use this product for high safety use.
  • Page 5 Only for the Japanese market: Although described in this manual, some sections do not apply to the Japanese market. These options and routines include: – USB Flash Module (UFM) – CSS (Customer Self Service) – Replacing the lithium battery Technical Manual D2952 (BX924 S2)
  • Page 6 Technical Manual D2952 (BX924 S2)
  • Page 7: Table Of Contents

    Settings with switches and jumpers ... . . 34 Replacing the lithium battery ....37 Technical Manual D2952 (BX924 S2)
  • Page 8 Contents Technical Manual D2952 (BX924 S2)
  • Page 9: Introduction

    For additional driver information (if available), refer to the supplied DVDs (see Installation DVD of ServerView Suite - ServerView Software Products). You will find further information about the BIOS setup in the "D2952 BIOS Setup Utility for PRIMERGY BX924 S2 Server Blade Reference Manual".
  • Page 10 Notational conventions Technical Manual D2952 (BX924 S2)
  • Page 11: Important Notes

    Information on which system expansions are approved for installation can be obtained from our customer service center or your sales outlet. The warranty expires if the device is damaged during the installation or replacement of system expansions. Technical Manual D2952 (BX924 S2)
  • Page 12 (this information doesn’t apply to the Japanese market). It is essential to observe the instructions in chapter "Replacing the lithium battery". Technical Manual D2952 (BX924 S2)
  • Page 13 Do not touch any connectors or conduction paths on an ESD. Place all the components on a pad which is free of electrostatic charge. For a detailed description of how to handle ESD components, see the relevant European or international standards (EN 61340-5-1, ANSI/ESD S20.20). Technical Manual D2952 (BX924 S2)
  • Page 14: Ce Certificate Of Conformity

    The board complies with the requirements of the EC directives 2004/108/EC regarding “Electromagnetic Compatibility” and 2006/95/EC “Low Voltage Directive”. This is indicated by the CE marking (CE = Communauté Européenne). Compliance was tested in a typical PRIMERGY configuration. Technical Manual D2952 (BX924 S2)
  • Page 15: Environmental Protection

    Environmental protection Environmental protection Environmentally-friendly product design and development This product has been designed in accordance with the Fujitsu standard for "environmentally friendly product design and development". This means that key factors such as durability, selection and labeling of materials, emissions, packaging, ease of dismantling and recycling have been taken into account.
  • Page 16 Details regarding the return and recycling of devices and consumables within Europe can also be found in the "Returning used devices" manual, via your local Fujitsu branch or from our recycling center in Paderborn: Fujitsu Technology Solutions Recycling Center D-33106 Paderborn Tel.
  • Page 17: Features

    – TPM 1.2 Infineon SLB9635 TT1.2 card (option) – Board Management controller iRMC S2 with integrated graphic controller – 2 MB Flash ROM – 32Mx16-667 DDR2 SRAM for iRMC S2 – ADT7462 temperature/system monitoring controller Technical Manual D2952 (BX924 S2)
  • Page 18 – HD LED support (SAS, SATA) – Inventory Identification Control – CSS functionality – Energy consumption control – Console redirection (text console) – Graphic console redirection (Advanced Video Redirection - AVR) – Provision of remote memory media (Remote Storage) Technical Manual D2952 (BX924 S2)
  • Page 19 – LAN – console redirection support – OEM logo – CPU, memory disable – Mirroring and Spare memory support Environmental protection Battery in holder for recycling Form factor, slot compatibility list – 490 x 199mm Technical Manual D2952 (BX924 S2)
  • Page 20 (e.g. drive encryption using Windows Bitlocker Drive Encryption). The TPM is activated via the BIOS system (for more information, refer to the “D2952 BIOS Setup Utility for BX924 S2" manual). CAUTION! – When using the TPM, note the program descriptions provided by the third party manufacturers.
  • Page 21: Main Memory

    The channels A - C are controlled by CPU 1 and the channels D - F are controlled by CPU 2. x4 or x8 organized registered (RDIMMs) or unbuffered (UDIMMs) memory modules with ECC are supported. Technical Manual D2952 (BX924 S2)
  • Page 22: Module Population

    The populated memory of the six channels (A - F) can be used completely. – Performance channel mode (maximum performance) The populated memory of the six channels (A - F) can be used completely. – Mirrored channel mode (maximum security) Technical Manual D2952 (BX924 S2)
  • Page 23 CPU 1 CPU 2 CPU 1 CPU 2 required optional, same type in bank per CPU optional, any type not used Performance Channel Mode requires 3 identical modules per bank Figure 4: Main memory operating modes Technical Manual D2952 (BX924 S2)
  • Page 24: Independent Channel Mode

    CPU 2: DIMM1D -> DIMM1E -> DIMM1F CPU 1: DIMM2A -> DIMM2B -> DIMM2C CPU 2: DIMM2D -> DIMM2E -> DIMM2F CPU 1: DIMM3A -> DIMM3B -> DIMM3C CPU 2: DIMM3D -> DIMM3E -> DIMM3F Technical Manual D2952 (BX924 S2)
  • Page 25: Performance Channel Mode

    The empty DIMM slots of CPU 1 must be fitted with dummy DIMM modules to ensure sufficient cooling of the system. In addition always an air duct has to be mounted to cover the DIMM modules and the dummy DIMM modules of CPU1. Technical Manual D2952 (BX924 S2)
  • Page 26: Spare Channel Mode

    The empty DIMM slots of CPU 1 must be fitted with dummy DIMM modules to ensure sufficient cooling of the system. In addition always an air duct has to be mounted to cover the DIMM modules and the dummy DIMM modules of CPU1. Technical Manual D2952 (BX924 S2)
  • Page 27: Memory Speed

    Mix of SR + DR * SR = single rank, DR = dual rank, QR = quad rank ** No memory modules released for this configuration *** Lost LV-mode memory will automatically switch to 1,5 V Vcc Technical Manual D2952 (BX924 S2)
  • Page 28: Screen Resolution

    Sensor monitoring The removal of, or a fault in, a temperature sensor is detected. Should this happen all fans monitored by this sensor run at maximum speed, to achieve the greatest possible protection of the hardware. Technical Manual D2952 (BX924 S2)
  • Page 29 LED and recorded in the System Event Log. The events can be retrieved in the BIOS Setup or via the ServerView Operations Manager. Diagnostic LEDs For signalisation of failures LEDs are situated on the system board. Technical Manual D2952 (BX924 S2)
  • Page 30: Led Indicators

    DIMMs 1D - 3F yellow Faulty memory module CPU 2 yellow CPU faulty CSS button none Activates the LEDs in case of an error CPU 1 yellow CPU faulty Mezzanine board 2 yellow Error on Mezzanine board 2 Technical Manual D2952 (BX924 S2)
  • Page 31: External Indicators

    LED indicators 3.5.2 External indicators Figure 6: External ports of the system board D2952 Pos. Name Pos. Name lighting lighting Power on green NIC LED green Power off orange Identification LED blue MEZZ 1 LED green Global Error LED amber...
  • Page 32: Interfaces, Connectors And User Switch

    DIMM 3D SATA1 SATA0 Mezzanine Card 2 CPU 2 CPU 1 Figure 7: Schematic view of the system board D2952 Battery Slot 1 for Mezzanine card 1 DIP-switch Slot for SATA 1 Memory slots 1A - 3C Slot for SATA 0...
  • Page 33 Interfaces, connectors and user switch External connectors Figure 8: External ports of the system board D2952 4-way connector USB, VGA, serial (Y cable) Technical Manual D2952 (BX924 S2)
  • Page 34: Settings With Switches And Jumpers

    BIOS setup (the Password on boot field is set to enabled in the SECURITY menu). The password prompt is skipped. The user-defined BIOS passwords are deleted. The password prompt is active (default setting). Technical Manual D2952 (BX924 S2)
  • Page 35 BIOS on the board. The system starts with the system BIOS of the system board (default setting). Switch 4 - (for service only) Switch 4 Flash descriptor override strap (for service only). Technical Manual D2952 (BX924 S2)
  • Page 36 Settings with switches and jumpers Technical Manual D2952 (BX924 S2)
  • Page 37: Replacing The Lithium Battery

    Ê Press the locking spring into direction of the arrow (1), so that the lithium battery jumps out of its socket. Ê Remove the battery (2). Ê Insert a new lithium battery of the same type into the socket (3) and (4). Technical Manual D2952 (BX924 S2)
  • Page 38 Technical Manual D2952 (BX924 S2)

Table of Contents