System Board D2440/D2932
for RX330 S1
Technical Manual
Edition June 2009

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu D2440

  • Page 1 System Board D2440/D2932 for RX330 S1 Technical Manual Edition June 2009...
  • Page 2 Gesellschaft für Technik-Dokumentation mbH www.cognitas.de Copyright and Trademarks Copyright © 2009 Fujitsu Technology Solutions GmbH. All rights reserved. Delivery subject to availability; right of technical modifications reserved. All hardware and software names used are trademarks of their respective manufacturers.
  • Page 3: Table Of Contents

    Replacing the lithium battery ....25 Abbreviations ....... 27 Technical Manual D2440/D2932 (RX330 S1)
  • Page 5: Introduction

    Introduction This technical manual describes the system boards D2440/D2932, which can ® be equipped with one or two AMD processors. Further information about drivers is provided in the readme files on the hard disk, on the supplied CDs or DVDs.
  • Page 7: Important Notes

    Information on which system expansions are suitable can be obtained from the customer service centre or your sales outlet. ● The warranty expires if the device is damaged during the installation or replacement of system expansions. Technical Manual D2440/D2932 (RX330 S1)
  • Page 8 Incorrect replacement of lithium battery may lead to a risk of ● explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer. It is essential to observe the instructions in chapter “Replacing the lithium battery”. Technical Manual D2440/D2932 (RX330 S1)
  • Page 9 ● Place all components on a static-safe base. You will find a detailed description for handling ESD components in the relevant European or international standards (EN 61340-5-1, ANSI/ESD S20.20). Technical Manual D2440/D2932 (RX330 S1)
  • Page 10: Ce Certificate

    Never use sharp objects (screwdrivers) for leverage. ● CE certificate The shipped version of this board complies with the requirements of the EEC directive 89/336/EEC „Electromagnetic compatibility“. Compliance was tested in a typical PRIMERGY configuration. Technical Manual D2440/D2932 (RX330 S1)
  • Page 11: Environmental Protection

    Cd Cadmium Hg Mercury Pb Lead Notes on labeling plastic housing parts Please avoid attaching your own labels to plastic housing parts wherever possible, since this makes it difficult to recycle them. Technical Manual D2440/D2932 (RX330 S1)
  • Page 12 You will find further information on this at http://ts.fujitsu.com/recycling. For details on returning and reuse of devices and consumables within Europe, refer to the “Returning used devices” manual, or contact your Fujitsu Technology Solutions branch office/subsidiary or our recycling centre in Paderborn: Fujitsu Technology Solutions...
  • Page 13: Features

    Features For the PRIMERGY RX330 S1 server the system boards D2440 and D2932 are available. The system boards differ in Firmware, processors and main memory. Overview Processors D2440 D2932 ® – 2 x AMD64 Opteron™ Dual Core – 2 x Opteron™ Quad Core or Quad Core („Barcelona“)
  • Page 14 – VGA port – 2 RJ45 LAN ports – Service LAN port PCI slots – slot for riser card – PCI Express x8 slot BIOS features – Phoenix-BIOS (Trusted Core) Form factor 304.8 mm x 330.2 mm Technical Manual D2440/D2932 (RX330 S1)
  • Page 15: Main Memory

    The system board supports up to 32 Gbyte main memory. 8 slots (4 banks with 2 modules) are available for the main memory. Each memory bank can be populated with 512 Mbyte (only D2440), 1 Gbyte, 2 Gbyte or 4 Gbyte ECC DDR2 SDRAM memory modules.The maximum main memory is 16 Gbyte for installation with one CPU and 32 GByte with two CPUs.
  • Page 16: Pci Bus

    PCI bus PCI Express x8 Figure 3: PCI slots PCI slots The following table shows an overview of the PCI slots: PCI slot Description PCI Express x8 slot Slots on riser card 1 or 2 Technical Manual D2440/D2932 (RX330 S1)
  • Page 17 An interrupt signal may thereby be used simultaneously by multiple devices (interrupt sharing). PCI Express devices send their interrupts through messages. This avoids restrictions in wiring. Technical Manual D2440/D2932 (RX330 S1)
  • Page 18 Assignment of the PCI interrupts If you select Auto in the BIOS setup, the interrupts are assigned automatically and no further settings are required. Technical Manual D2440/D2932 (RX330 S1)
  • Page 19: Screen Resolution

    Measurement of the processor temperature, the system board temperature by an onboard sensor and measurement of the ambient temperature by a temperature sensor. Fan monitoring Fans that are no longer available, blocked or sticky fans are detected. Technical Manual D2440/D2932 (RX330 S1)
  • Page 20 However, this will only be indicated when the system is switched on again System Event Log (SEL) All monitored events of the system board are recorded in the System Event Log. They could be retrieved after a system reboot via ServerView. Technical Manual D2440/D2932 (RX330 S1)
  • Page 21: Connectors And Dip Switches

    DIMM3B Battery 1 2 3 4 SATA1 SAS1 SAS2 SAS3 SAS4 SAS5 SAS6 Figure 4: Schematic overview of the system boards D2440/D2932 1 = J10 - power supply CPU 2 12 = SAS3 2 = J25 - power supply I...
  • Page 22 Switch 4 Recovery OFF The System BIOS is started with the system BIOS from the system board (default). The system boots from the „Flash BIOS floppy disk“ and reprograms the system BIOS on the system board. Technical Manual D2440/D2932 (RX330 S1)
  • Page 23: External Connectors

    Features Connectors and DIP switches 3.6.1 External connectors Figure 5: External connectors of the system boards D2440/D2932 1 = PS/2 mouse port 6 = LAN port 1 2 = Serial port COM2 7 = USB port 3 = USB port 2...
  • Page 24 Figure 7: LAN connector Service LAN controller 1 LAN link/activity green LAN connection no LAN connection flashing LAN transfer 2 LAN transfer rate green transfer rate 10 Mbit/s (or no connection) transfer rate 100 Mbit/s Technical Manual D2440/D2932 (RX330 S1)
  • Page 25: Replacing The Lithium Battery

    Ê Press the locking spring into direction of the arrow (1), so that the lithium- battery jumps out of its socket. Ê Remove the battery (2). Ê Insert a new lithium battery of the same type into the socket (3) and (4). Technical Manual D2440/D2932 (RX330 S1)
  • Page 27: Abbreviations

    ANSI American National Standards Institute ASR&R Automatic Server Recovery and Restart Advanced Technology Attachment Battery Backup Unit BIOS Basic Input Output System Baseboard Management Controller CMOS Complementary Metal Oxide Semiconductor COMmunication port Central Processing Unit Technical Manual D2440/D2932 (RX330 S1)
  • Page 28 Error Correction Code EEPROM Electrical Erasable Programmable Read Only Memory Extensible Firmware Interface Elektrostatisch gefährdete Bauteile EHCI Enhanced Host Controller Interface Electromagnetic interference EMRL Embedded RAID Logic Elektromagnetische Verträglichkeit (electromagnetic compatibility) EPROM Erasable Programmable Read Only Memory Technical Manual D2440/D2932 (RX330 S1)
  • Page 29 Front Side Bus In Circuit Emulation Integrated (intelligent) Drive Electronics International Electrotechnical Commission Integrated Mirroring Enhanced IOOP Intelligent Organisation Of PCI IPMB Intelligent Platform Management Bus IPMI Intelligent Platform Management Interface iRMC integrated Remote Management Controller Technical Manual D2440/D2932 (RX330 S1)
  • Page 30 Multi Processor Specification Non Maskable Interrupt Original Equipment Manufacturer OHCI Open Host Controller Interface Operating System Peripheral Components Interconnect Prefailure Detection and Analyzing Programmed Input Output Power Distribution Board Programmable Logic Device PS(U) Power Supply (Unit) Technical Manual D2440/D2932 (RX330 S1)
  • Page 31 RAID on Motherboard Remote Service Board ReSeT Real Time Clock Serial Attached SCSI SATA Serial ATA SCSI Small Computer Systems Interface SDDC Single Device Data Correction SDRAM Synchronous Dynamic Random Access Memory System Event Log Technical Manual D2440/D2932 (RX330 S1)
  • Page 32 Symmetrical Multi Processing UHCI Unified Host Controller Interface Universal Serial Bus Video Graphics Adapter Voltage Regulator Down Voltage Regulator Module WEEE Waste from Electric and Electronic Equipment (EU Directive) Wired for Management Wake up On LAN Technical Manual D2440/D2932 (RX330 S1)

This manual is also suitable for:

D2932

Table of Contents