PRIMERGY
Susanne Däschlein
Fujitsu Siemens Computers GmbH
München
81730 München
e-mail: email: manuals@fujitsu-siemens.com
Tel.: (089) 61001-155
Fax: (++49) 700 / 372 00000
D2239 (TX150 S4)
Sprachen: En

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu D2239

  • Page 1 PRIMERGY Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001-155 Fax: (++49) 700 / 372 00000 D2239 (TX150 S4) Sprachen: En...
  • Page 2 Gesellschaft für Technik-Dokumentation mbH www.cognitas.de Copyright and Trademarks Copyright © 2006 Fujitsu Siemens Computers GmbH. All rights reserved. Delivery subject to availability; right of technical modifications reserved. All hardware and software names used are trademarks of their respective manufacturers.
  • Page 3: Table Of Contents

    Replacing the lithium battery ....Abbreviations ....... Technical Manual D2239 (TX150 S4)
  • Page 5: Introduction

    Introduction This technical manual describes the system board D2239, which can be ® equipped with one Intel processor. You will find further information in the manual “BIOS Setup”. Further information about drivers is provided in the readme files on the hard disk, on the supplied “ServerSupport”...
  • Page 7: Important Notes

    Information on which system expansions are suitable can be obtained from the customer service centre or your sales outlet. The warranty expires if the device is damaged during the installation or replacement of system expansions. Technical Manual D2239 (TX150 S4)
  • Page 8 Incorrect replacement of lithium battery may lead to a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer. It is essential to observe the instructions in chapter “Replacing the lithium battery”. Technical Manual D2239 (TX150 S4)
  • Page 9 Place all components on a static-safe base. You will find a detailed description for handling ESD components in the relevant European or international standards (EN 61340-5-1, ANSI/ESD S20.20). Technical Manual D2239 (TX150 S4)
  • Page 10: Ce Certificate

    Never use sharp objects (screwdrivers) for leverage. CE Certificate The shipped version of this board complies with the requirements of the EEC directive 89/336/EEC “Electromagnetic compatibility”. Compliance was tested in a typical PRIMERGY configuration. Technical Manual D2239 (TX150 S4)
  • Page 11: Environmental Protection

    Cd Cadmium Hg Mercury Pb Lead Notes on labeling plastic housing parts Please avoid attaching your own labels to plastic housing parts wherever possible, since this makes it difficult to recycle them. Technical Manual D2239 (TX150 S4)
  • Page 12 You will find further information on this at www.fujitsu- siemens.com/recycling. For details on returning and reuse of devices and consumables within Europe, refer to the “Returning used devices” manual, or contact your Fujitsu Siemens Computers branch office/subsidiary or our recycling centre in Paderborn: Fujitsu Siemens Computers...
  • Page 13: Features

    Features Overview The system board D2239 is available in two versions: – SCSI version; you will find on the system board a SCSI controller and one SCSI connector – SATA version; four SATA connectors and one SATA LED connector Processors ®...
  • Page 14 – 2 x PCI-X (64 Bit / 66 MHz), slot 2 prepared for ZCR (ZCR only possible in SCSI version) – 3 x PCI (32 Bit / 33 MHz) – 1 x PCI Express x1 (short, 0.5 GB/s) – 1 x PCI Express x4 (2 GB/s) Technical Manual D2239 (TX150 S4)
  • Page 15 Environmental protection Battery in holder Form factor, slot compatibility list – ATX-L – ACPI 1.0b, OnNow, PCI 2.3, PCI-X1.0b, PCI-X2.0, PCI Express 1.0a, WfM 2.0, SHDG 3.0, MPS 1.4, IPMI 1.5, PCI SHPC 1.0, USB2.0 Technical Manual D2239 (TX150 S4)
  • Page 16: Main Memory

    DIMM_2A DIMM_1B DIMM_2B populated empty empty empty single empty populated empty empty channel empty empty populated empty empty empty empty populated populated empty populated empty dual channel empty populated empty populated populated populated populated populated Technical Manual D2239 (TX150 S4)
  • Page 17: Pci Bus

    Zero Channel RAID (only SCSI version) PCI slot 2 is prepared for Zero Channel RAID (ZCR). ZCR means that the oboard SCSI controller can be upgraded to a SCSI RAID controller through the inserted ZCR PCI card. Technical Manual D2239 (TX150 S4)
  • Page 18 3, 4, 5, 6, 7, 9, 10, 11, 12, 14, 15 The selected ISA interrupt is assigned to the PCI interrupt. You may not select an ISA interrupt that is used by a component on the system board (e.g. controller) or an ISA board. Technical Manual D2239 (TX150 S4)
  • Page 19 PCI PCI-X PCI-X PCI PCI LINE 1st 2nd 3rd 4th PXH-V (ZCR PXH-V ICH ICH ICH ICH 1 (A) 2 (B) 3 (C) 4 (D) 5 (E) 6 (F) 7 (G) 8 (H) x IDSel *) only SCSI version Technical Manual D2239 (TX150 S4)
  • Page 20: Screen Resolution

    Measurement of the processor and the inhouse temperature by an onboard sensor, measurement of the ambient temperature by a I²C temperature sensor. Fan monitoring Fans that are no longer available, blocked or sticky fans are detected. Fan control The fans are regulated according to temperature. Technical Manual D2239 (TX150 S4)
  • Page 21 However, this will only be indicated when the system is switched on again System Event Log (SEL) All monitored events of the system board are recorded in the System Event Log. They could be retrieved after a reboot via ServerView. Technical Manual D2239 (TX150 S4)
  • Page 22: Interfaces And Connectors

    Interfaces and connectors Features Interfaces and connectors Figure 4: Schematic view of the system board D2239 - SCSI version 1 = CPU fan 11 = Intrusion detection 2 = Floppy disk drive 12 = SMB1 (I²C temperature sensor) 3 = Front panel...
  • Page 23 Features Interfaces and connectors Figure 5: Schematic view of the system board D2239 - SATA version 1 = CPU fan 10b = SATA LED 2 = Floppy disk drive 11 = Intrusion detection 3 = Front panel 12 = SMB1 (I²C temperature sensor)
  • Page 24: Settings With Jumpers

    Skip password (enabled) RCVR: Recover system BIOS (enabled) 3.6.2 External connectors Figure 7: External ports of the system board D2239 1 = PS/2 mouse port 6 = Serial port COM2 2 = Parallel port 7 = Serial port COM1 3 = LAN port...
  • Page 25 Intel PXE is supported. The LAN port serves as management interface and is prepared for RemoteView. The LAN controller connectors are equipped with two LEDs (light emitting diode) indicating the transfer rate and the activity. Technical Manual D2239 (TX150 S4)
  • Page 26 LAN connection LAN link/activity no LAN connection flashing LAN transfer green + transfer rate 10 Mbit/s yellow (or no connection) 2 LAN transfer rate green transfer rate 100 Mbit/s yellow transfer rate 1000 Mbit/s Technical Manual D2239 (TX150 S4)
  • Page 27: Replacing The Lithium Battery

    Ê Press the locking spring into direction of the arrow (1), so that the lithium- battery jumps out of its socket. Ê Remove the battery (2). Ê Insert a new lithium battery of the same type into the socket (3) and (4). Technical Manual D2239 (TX150 S4)
  • Page 29: Abbreviations

    Automatic Server Recovery and Restart Advanced Technology Attachment Battery Backup Unit BIOS Basic Input Output System Baseboard Management Controller CMOS Complementary Metal Oxide Semiconductor COMmunication port Central Processing Unit Double Data Rate DIMM Dual In-line Memory Module Technical Manual D2239 (TX150 S4)
  • Page 30 EPROM Erasable Programmable Read Only Memory EMRL Embedded RAID Logic EVRD Enterprise VRD Hot-plug Controller In Circuit Emulation Integrated (intelligent) Drive Electronics Integrated Mirror Enhanced IOOP Intelligent Organization Of PCI IPMB Intelligent Platform Management Bus Technical Manual D2239 (TX150 S4)
  • Page 31 Multi Processor Specification Non Maskable Interrupt Original Equipment Manufacturer OHCI Open Host Controller Interface Operating System Peripheral Components Interconnect Prefailure Detection and Analyzing Programmed Input Output Programmable Logic Device PS(U) Power Supply (Unit) Puls Wide Modulation Technical Manual D2239 (TX150 S4)
  • Page 32 SCSI Small Computer Systems Interface SDDC Single Device Data Correction SDRAM Synchronous Dynamic Random Access Memory SHDG Server Hardware Design Guide System Management Bus Server Management Mode Symmetrically Multi Processing UHCI Unified Host Controller Interface Technical Manual D2239 (TX150 S4)
  • Page 33 Abbreviations Universal Serial Bus Video Graphics Adapter Voltage Regulator Down Voltage Regulator Module Wired for Management Wake up On LAN Technical Manual D2239 (TX150 S4)
  • Page 35 Comments Suggestions Corrections Fax: (++49) 700 / 372 00000 Comments on System Board D2239 for TX150 S4 D2239 (TX150 S4)
  • Page 37 Comments Suggestions Corrections Fax: (++49) 700 / 372 00000 Comments on System Board D2239 for TX150 S4 D2239 (TX150 S4)
  • Page 39 Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Compu- ters. This new subsidiary of Fujitsu has been renamed Fujitsu Technology So- lutions. This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed.