System Board D2519
for RX300 S4
Technical Manual
Edition August 2008

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu D2519

  • Page 1 System Board D2519 for RX300 S4 Technical Manual Edition August 2008...
  • Page 2 Comments… Suggestions… Corrections… The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs. Feel free to send us your comments by e-mail to manuals@fujtsu-siemens.com. Certified documentation according to DIN EN ISO 9001:2000 To ensure a consistently high quality standard and user-friendliness, this documentation was created to...
  • Page 3: Table Of Contents

    Replacing the lithium battery ....33 Abbreviations ....... 35 Technical Manual D2519 (RX300 S4)
  • Page 5: Introduction

    Introduction This technical manual describes the system board D2519, which is equipped ® with one Intel processor. Further information about drivers is provided in the readme files on the hard disk, on the supplied “ServerStart“ or “Update“ CDs. You will find further information in the BIOS description.
  • Page 7: Important Notes

    Information on which system expansions are suitable can be obtained from the customer service centre or your sales outlet. The warranty expires if the device is damaged during the installation or replacement of system expansions. Technical Manual D2519 (RX300 S4)
  • Page 8 Incorrect replacement of lithium battery may lead to a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer. It is essential to observe the instructions in chapter “Replacing the lithium battery”. Technical Manual D2519 (RX300 S4)
  • Page 9 Place all components on a static-safe base. You will find a detailed description for handling ESD components in the relevant European or international standards (EN 61340-5-1, ANSI/ESD S20.20). Technical Manual D2519 (RX300 S4)
  • Page 10: Ce Certificate

    Never use sharp objects (screwdrivers) for leverage. CE Certificate The shipped version of this board complies with the requirements of the EEC directive 89/336/EEC "Electromagnetic compatibility". Compliance was tested in a typical PRIMERGY configuration. Technical Manual D2519 (RX300 S4)
  • Page 11: Environmental Protection

    Cd Cadmium Hg Mercury Pb Lead Notes on labeling plastic housing parts Please avoid attaching your own labels to plastic housing parts wherever possible, since this makes it difficult to recycle them. Technical Manual D2519 (RX300 S4)
  • Page 12 You will find further information on this at www.fujitsu- siemens.com/recycling. For details on returning and reuse of devices and consumables within Europe, refer to the “Returning used devices” manual, or contact your Fujitsu Siemens Computers branch office/subsidiary or our recycling centre in Paderborn: Fujitsu Siemens Computers...
  • Page 13: Features

    – local BIOS update via optional device (floppy disk, ODD, USB stick) – remote BIOS update via LAN – 1 Service LAN controller SMSC8700 Fast Ethernet – iPMI S2 with integrated VGA graphic controller (VESA compatible) Technical Manual D2519 (RX300 S4)
  • Page 14 – 1 x PCI-X – 6 x PCI Express BIOS features – Phoenix System BIOS V 4.06 – SMBIOS 2.4 (DMI) – MultiProcessor specification – Server Hardware Design Guide – WfM – ACPI support – USB keyboard/mouse Technical Manual D2519 (RX300 S4)
  • Page 15 (e.g. drive encryption using Windows Bitlocker Drive Encryption). The TPM is activated via the BIOS system (for more information, refer to the Fujitsu Siemens Computers BIOS manual). CAUTION! – When using the TPM, note the program descriptions provided by the third party manufacturers.
  • Page 16 TPM or the system board is faulty you will not be able to access your data. – If a failure occurs, please inform your service about the TPM activation before it takes any action, and be prepared to provide them with your backup copies of the TPM content. Technical Manual D2519 (RX300 S4)
  • Page 17: Main Memory

    DIMM 2B DIMM 2C DIMM 2A DIMM 1D DIMM 1B DIMM 1C DIMM 1A Figure 2: Assembly of the main memory with memory banks and memory modules when LED is ON the memory module is faulty Technical Manual D2519 (RX300 S4)
  • Page 18 – One pair of memory modules must consist of identical memory modules. – The module capacity between pairs can differ: pair 2A/2B can be populated with two 512 Mbyte modules and pair 1A/1B with two 1 Gbyte modules. Technical Manual D2519 (RX300 S4)
  • Page 19 3C + 3D Consecutive population 1A + 1B (minimum configuration) 2A + 2B 3A + 3B 1C + 1D 2C + 2D 3C + 3D Table 2: Alternate and consecutive population with 2 riser cards Technical Manual D2519 (RX300 S4)
  • Page 20 In mirrored mode always four identical memory modules are necessary, two in each riser card: 1A + 1B, 1C + 1D (minimum configuration) 2A + 2B, 2C + 2D; 3A + 3B, 3C + 3D (upgrade) Technical Manual D2519 (RX300 S4)
  • Page 21: Pci Bus

    PCI e x4 slot PCI e x4 slot PCI e x4 slot (slot 3 free: x8) 64 bit 32-Bit PCI slot PCI e x4 slot PCI e x4 slot (slot 5 free: x8) PCI e x4 slot Technical Manual D2519 (RX300 S4)
  • Page 22 Slot 1 is the preferred slot for the HDD controller (bootable). Assignment of the PCI interrupts If you select Auto in the BIOS setup, the interrupts are assigned automatically and no further settings are required. Technical Manual D2519 (RX300 S4)
  • Page 23: Screen Resolution

    C temperature sensor. Fan monitoring The CPU, power supply unit and system fans are monitored. Fans that are no longer available, blocked or sticky fans are detected. Technical Manual D2519 (RX300 S4)
  • Page 24 All monitored events of the system board are signalized via the Global Error LED and recorded in the System Event Log. They could be retrieved in the BIOS Setup or via ServerView. Diagnostic LEDs For signalisation of failures LEDs are situated on the system board. Technical Manual D2519 (RX300 S4)
  • Page 25: Leds

    LED s A, B, C, D, E and F are visible from outside on the rear of the server. All the other LEDs are only visible, if the cover of the server has been opened. Technical Manual D2519 (RX300 S4)
  • Page 26 OK orange fan failure iRMC green iRMC (integrated Remote Management flashing Controller) is okay Board Error System board is faulty Main Power green main power is OK Aux Power yellow auxiliary power is OK Technical Manual D2519 (RX300 S4)
  • Page 27 Features LEDs By pressing the CSS tracer (to position see next side) the defective component can also be indicated in the power-off condition (power supply plug discon- nected). Technical Manual D2519 (RX300 S4)
  • Page 28: Interfaces And Connectors

    CPU 2 Fan 3 CPU Fan 1 sys Fan 1 CPU Fan 2 CPU Fan 4 CPU Fan 6 CPU Fan 2 sys Fan 5 CPU Figure 5: Schematic view of the system board D2519 Technical Manual D2519 (RX300 S4)
  • Page 29: External Ports

    23 = PCI slots 12 = USB 24 = external connectors 3.7.1 External ports Figure 6: External ports of the system board D2519 1 = CSS LED (yellow) 6 = USB port 1 Global Error LED (red) Identification LED (blue)
  • Page 30 Figure 7: LAN connector system LAN controller 1 LAN transfer rate green + transfer rate 10 Mbit/s yellow green transfer rate 100 Mbit/s yellow transfer rate 1000 Mbit/s 2 LAN link/activity green LAN connection no LAN connection flashing LAN transfer Technical Manual D2519 (RX300 S4)
  • Page 31 Interfaces and connectors Figure 8: LAN connector service LAN controller 1 LAN transfer rate green transfer rate 10 Mbit/s green transfer rate 100 Mbit/s 2 LAN link/activity green LAN connection no LAN connection flashing LAN transfer Technical Manual D2519 (RX300 S4)
  • Page 32: Settings With Jumpers

    Settings with jumpers 1 2 3 4 Figure 9: Jumpers Recovering system BIOS - switch 1 Switch 1 enables recovery of the old system BIOS after an attempt to update has failed. To restore the old system BIOS you need a Flash BIOS medium (please call our customer service centre).
  • Page 33 To write and delete floppy disks, the write-protection in BIOS Setup must be disabled (in menu Security, the field Diskette Write must be set to Enabled). The floppy disk drive is write-protected. Floppy disks can be read, written and deleted (default setting). Technical Manual D2519 (RX300 S4)
  • Page 34 Settings with jumpers Features Technical Manual D2519 (RX300 S4)
  • Page 35: Replacing The Lithium Battery

    Ê Press the locking spring into direction of the arrow (1), so that the lithium battery jumps out of its socket. Ê Remove the battery (2). Ê Insert a new lithium battery of the same type into the socket (3) and (4). Technical Manual D2519 (RX300 S4)
  • Page 37: Abbreviations

    Automatic Server Recovery and Restart Advanced Technology Attachment Battery Backup Unit BIOS Basic Input Output System Baseboard Management Controller CMOS Complementary Metal Oxide Semiconductor COMmunication port Computer Self Service Central Processing Unit Double Data Rate Technical Manual D2519 (RX300 S4)
  • Page 38 Dynamic Random Access Memory Error Correction Code EEPROM Electrical Erasable Programmable Read Only Memory EPROM Erasable Programmable Read Only Memory EMRL Embedded RAID Logic Fully Buffered DIMM Front Side Bus EVRD Enterprise VRD Hot-plug Controller In Circuit Emulation Technical Manual D2519 (RX300 S4)
  • Page 39 Intelligent Platform Management Interface iRMC integrated Remote Management Controller Local Area Network Light Emitting Diode Multi Processor Specification Non Maskable Interrupt NVRAM Non Volatile RAM Original Equipment Manufacturer Optical Disk Drive OHCI Open Host Controller Interface Technical Manual D2519 (RX300 S4)
  • Page 40 Programmed Input Output Programmable Logic Device PS(U) Power Supply (Unit) Puls Wide Modulation Preboot eXecution Environment RAID Redundant Array of Inexpensive Disks Remote Service Board ReSeT Real Time Clock Serial Attached SCSI SATA Serial ATA Technical Manual D2519 (RX300 S4)
  • Page 41 Server Hardware Design Guide SHPC Standard Hot Plug Controller System Management Bus Server Management Mode Symmetrically Multi Processing Trusted Platform Module UHCI Unified Host Controller Interface Universal Serial Bus Video Graphics Adapter Voltage Regulator Down Voltage Regulator Module Technical Manual D2519 (RX300 S4)
  • Page 42 Wired for Management Wake up On LAN...
  • Page 43 Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Compu- ters. This new subsidiary of Fujitsu has been renamed Fujitsu Technology So- lutions. This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed.

Table of Contents