Fujitsu D2786 Technical Manual

System board for rx200 s5

Advertisement

System Board D2786
for RX200 S5
Technical Manual
Edition April 2009

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu D2786

  • Page 1 System Board D2786 for RX200 S5 Technical Manual Edition April 2009...
  • Page 2 Your feedback helps us optimize our documentation to suit your individual needs. Feel free to send us your comments by e-mail to manuals@ts.fujitsu.com. Certified documentation according to DIN EN ISO 9001:2000 To ensure a consistently high quality standard and...
  • Page 3: Table Of Contents

    Replacing the lithium battery ....33 Abbreviations ....... 35 Technical Manual D2786 (RX200 S5)
  • Page 5: Introduction

    Introduction This technical manual describes the system board D2786, which is equipped with one or two Intel® processors. Further information you will find in the "BIOS Setup“. For additional driver information, refer to the Readme files located on the server hard disk and on the supplied CDs or DVDs.
  • Page 7: Important Notes

    Information on which system expansions are approved for installation can be obtained from our customer service center or your sales outlet. The warranty expires if the device is damaged during the installation or replacement of system expansions. Technical Manual D2786 (RX200 S5)
  • Page 8 Incorrect replacement of lithium battery may lead to a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer. It is essential to observe the instructions in the chapter “Replacing the lithium battery”. Technical Manual D2786 (RX200 S5)
  • Page 9 Place all components on a static-free surface. You will find a detailed description for handling ESD components in the relevant European or international standards (EN 61340-5-1, ANSI/ESD S20.20). Technical Manual D2786 (RX200 S5)
  • Page 10: Ce Certificate Of Conformity

    The board complies with the requirements of the EC directives 2004/108/EC regarding “Electromagnetic Compatibility” and 2006/95/EC “Low Voltage Directive”. This is indicated by the CE marking (CE = Communauté Européenne). Compliance was tested in a typical PRIMERGY configuration. Technical Manual D2786 (RX200 S5)
  • Page 11: Environmental Protection

    Cd Cadmium Hg Mercury Pb Lead Labels on plastic casing parts Please avoid sticking your own labels on plastic parts wherever possible, since this makes it difficult to recycle them. Technical Manual D2786 (RX200 S5)
  • Page 12 Details regarding the return and recycling of devices and consumables within Europe can also be found in the "Returning used devices" manual, via your local Fujitsu Technology Solutions branch or from our recycling center in Paderborn: Fujitsu Technology Solutions Recycling Center D-33106 Paderborn Tel.
  • Page 13: Features

    – memory mirroring function – memory sparing function Chips on the system board – Intel® Tylersburg 24D chipset – Intel® IOH (north bridge) – Intel® ICH10R (south bridge) ® – dual-port 1Gbit Ethernet LAN controllers Intel 82575EB Technical Manual D2786 (RX200 S5)
  • Page 14 – 1x serial interface (COM) – 3x USB connectors – 1x VGA connector – 2x RJ45 LAN connectors – 1x RJ45 service LAN connector – Front side – 3x USB connectors – 1x VGA connector Technical Manual D2786 (RX200 S5)
  • Page 15 – USB drive – LAN (PXE and iSCSI) – console redirection support – OEM logo – CPU, memory disable – memory mirroring and memory sparing support Environmental protection Battery in holder Form factor 431 x 717 mm Technical Manual D2786 (RX200 S5)
  • Page 16 TPM or the system board is faulty you will not be able to access your data. – If a failure occurs, please inform your service about the TPM activation before it takes any action, and be prepared to provide them with your backup copies of the TPM content. Technical Manual D2786 (RX200 S5)
  • Page 17: Main Memory

    DIMM 1C DIMM 2C DIMM 1B CPU 2 DIMM 2B DIMM 1A DIMM 2A DIMM 2D DIMM 1D DIMM 2E CPU 1 DIMM 1E DIMM 2F DIMM 1F Figure 2: Slots of the main memory Technical Manual D2786 (RX200 S5)
  • Page 18: Module Population

    – Allows population of all channels in any order. Related to the channels (A-F) DIMM1 must be populated first. – Works with DIMMs of different clock rates and applies the lowest clock rate. – Works with UDIMMs as well as RDIMMs. Technical Manual D2786 (RX200 S5)
  • Page 19 – Requires identical modules on all channels of each bank per CPU. – One third of the capacity is used as spare range — this means the main memory for the applications is reduced to two third. – RDIMMs are supported. Technical Manual D2786 (RX200 S5)
  • Page 20: Pci Slots

    Slot 1 DIMM 1A DIMM 2A CPU 1 Figure 4: PCI slots PCI slot Description PCI Express x8 (standard profile, half-length) PCI Express x8 (low profile, half-length) PCI Express x4 - mechanically x8 (low profile, half-length) Technical Manual D2786 (RX200 S5)
  • Page 21: Screen Resolution

    Screen resolution Refresh rate (Hz) Max. number of colours 640x480 32 bit 800x600 32 bit 1024x768 32 bit 1152x864 24 bit 1280x1024 24 bit 1600x1200 16 bit Technical Manual D2786 (RX200 S5)
  • Page 22: Temperature / System Monitoring

    All monitored events of the system board are signalised via the Global Error LED and recorded in the System Event Log. They could be retrieved in the BIOS Setup or via the ServerView Operations Manager. Technical Manual D2786 (RX200 S5)
  • Page 23: Connectors And Indicators

    Features Connectors and indicators Connectors and indicators 3.6.1 System board Figure 5: Internal connectors of the system board D2786 Technical Manual D2786 (RX200 S5)
  • Page 24 PSU I C connector CN11 SATA1 HDD connector (4 ports) CN13 PSU main connector SATA2 SATA ODD connector Connector for front panel JP4, JP6, System fan connectors JP7, JP10, JP11, JP12 CN30 Connector for TPM Technical Manual D2786 (RX200 S5)
  • Page 25 Features Connectors and indicators Figure 6: Indicators on the system board and indicate CSS button Technical Manual D2786 (RX200 S5)
  • Page 26 If the server has been powered off (power-plugs must be disconnected) it is possible to indicate the faulty component by pressing the indicate CSS button. It is required that the server has been without power no longer than 24 hours. Technical Manual D2786 (RX200 S5)
  • Page 27: Connector Panel

    S2) and is prepared for operation with the Remote Management. Optionally LAN connector 1 can also be used for iRMC S2 server management. Each LAN connector has two LEDs which display the speed of the connection and its status: Technical Manual D2786 (RX200 S5)
  • Page 28 Flashes yellow in the event of a LAN transfer rate of 1 Gbps rate Steady green signal in the event of a LAN transfer rate of (standard 100 Mbps. LAN) Remains dark in the event of a LAN transfer rate of 10 Mbps. Technical Manual D2786 (RX200 S5)
  • Page 29: Jumpers And Switches

    Slot 2 Slot 3 Battery DIMM 1C DIMM 2C DIMM 1B DIMM 2B Slot 1 DIMM 1A DIMM 2A CPU 1 Figure 9: Jumpers and switches The default setting for all jumpers is position 1-2. Technical Manual D2786 (RX200 S5)
  • Page 30 Ê During the POST process press [F2] in order to enter the Setup Utility. Ê Press [F9] to set the system defaults. Ê Press [F10] to save your changes and to exit the Setup Utility. Technical Manual D2786 (RX200 S5)
  • Page 31 Password enabled S1-3 BIOS write- BIOS can only be read protect BIOS can both be read and written to S1-4 CMOS clear Clear CMOS settings (software) and restore system defaults Normal CMOS settings Technical Manual D2786 (RX200 S5)
  • Page 33: Replacing The Lithium Battery

    Ê Press the locking spring into direction of the arrow (1), so that the lithium- battery jumps out of its socket. Ê Remove the battery (2). Ê Insert a new lithium battery of the same type into the socket (3) and (4). Technical Manual D2786 (RX200 S5)
  • Page 35: Abbreviations

    Automatic Server Recovery and Restart Advanced Technology Attachment Battery Backup Unit BIOS Basic Input Output System Baseboard Management Controller CMOS Complementary Metal Oxide Semiconductor COMmunication port Customer Replaceable Unit Customer Self Service Central Processing Unit Technical Manual D2786 (RX200 S5)
  • Page 36 Dynamic Random Access Memory Error Correction Code EEPROM Electrical Erasable Programmable Read Only Memory EPROM Erasable Programmable Read Only Memory EMRL Embedded RAID Logic Electrostatic Discharge EVRD Enterprise Voltage Regulator Down Fully Buffered DIMM Hard Disk Drive Technical Manual D2786 (RX200 S5)
  • Page 37 Intelligent Organization Of PCI IPMB Intelligent Platform Management Bus IPMI Intelligent Platform Management Interface iRMC integrated Remote Management Controller Local Area Network Light Emitting Diode Memory Controller Hub Multi Processor Specification Non Maskable Interrupt Network Operating System Technical Manual D2786 (RX200 S5)
  • Page 38 Operating System Peripheral Components Interconnect Prefailure Detection and Analyzing Programmed Input Output Programmable Logic Device POST Power-On Self Test PS(U) Power Supply (Unit) Pulse Wide Modulation Preboot eXecution Environment RAID Redundant Array of Inexpensive Disks Technical Manual D2786 (RX200 S5)
  • Page 39 SCSI Small Computer Systems Interface SDDC Single Device Data Correction SDRAM Synchronous Dynamic Random Access Memory SHDG Server Hardware Design Guide SHPC Standard Hot Plug Controller System Management Bus Server Management Mode Symmetrically Multi Processing Technical Manual D2786 (RX200 S5)
  • Page 40 Abbreviations Trusted Platform Module USB Flash Module UHCI Unified Host Controller Interface Universal Serial Bus Video Graphics Adapter Voltage Regulator Down Voltage Regulator Module Wired for Management Wake up On LAN Technical Manual D2786 (RX200 S5)

Table of Contents