Func-
Parameter
tion
80
Motor capacity
81
Number of motor poles
82
Motor excitation current
83
Motor rated voltage
84
Rated motor frequency
89
Speed control gain (magnetic flux vector)
90
Motor constant (R1)
91
Motor constant (R2)
92
Motor constant (L1)
93
Motor constant (L2)
94
Motor constant (X)
95
Online auto tuning selection
96
Auto tuning setting/status
100
V/F1(first frequency)
101
V/F1(first frequency voltage)
102
V/F2(second frequency)
103
V/F2(second frequency voltage)
104
V/F3(third frequency)
105
V/F3(third frequency voltage)
106
V/F4(fourth frequency)
107
V/F4(fourth frequency voltage)
108
V/F5(fifth frequency)
109
V/F5(fifth frequency voltage)
110
Third acceleration/deceleration time
111
Third deceleration time
112
Third torque boost
113
Third V/F (base frequency)
114
Third stall prevention operation current 0 to 220%
Thrid stall prevention operation
115
frequency
116
Third output frequency detection
117
PU communication station
118
PU communication speed
119
PU communication stop bit length
120
PU communication parity check
121
Number of PU communication retries
122
PU communication check time interval
123
PU communication waiting time setting 0 to 150ms, 9999
PU communication CR/LF presence/
124
absence selection
Terminal 2 frequency setting gain
125
frequency
Terminal 4 frequency setting gain
126
frequency
31
Name
Setting Range
0.4 to 55kW, 9999/
0 to 3600kW, 9999
2, 4, 6, 12, 14, 16, 9999
0 to 500A, 9999/
0 to 3600A, 9999
0 to 1000V
10 to 120Hz
0 to 200%
0 to 50
0 to 400mΩ, 9999
0 to 50
0 to 400mΩ, 9999
0 to 50
0 to 3600mΩ (0 to 400mH), 9999
0 to 50
0 to 3600mΩ (0 to 400mH), 9999
0 to 500
0 to 100Ω (0 to 100%), 9999
0 to 2
0, 1, 101
0 to 400Hz, 9999
0 to 1,000V
0 to 400Hz, 9999
0 to 1,000V
0 to 400Hz, 9999
0 to 1,000V
0 to 400Hz, 9999
0 to 1,000V
0 to 400Hz, 9999
0 to 1,000V
0 to 3600/360s, 9999
0 to 3600/360s, 9999
0 to 30%, 9999
0 to 400Hz, 9999
0 to 400Hz
0 to 400Hz
0 to 31
48, 96, 192, 384
0, 1, 10, 11
0, 1, 2
0 to10, 9999
0, 0.1 to 999.8s, 9999
0, 1, 2
0 to 400Hz
0 to 400Hz
Minimum
Setting
Increments
0.01/0.1kW
*2
*2
1
0.01/0.1A
*2
*2
0.1V
0.01Hz
0.1%
0.001Ω/
, 9999/
0.01mΩ
*2
*2
0.001Ω/
, 9999/
0.01mΩ
*2
*2
0.001Ω (0.1mH)/
(0 to 1000mH), 9999/
0.01mΩ(0.01mH)
*2
*2
0.001Ω (0.1mH)/
(0 to 1000mH), 9999/
0.01mΩ(0.01mH)
*2
*2
0.01Ω (0.1%)/
(0 to 100%), 9999/
0.01Ω (0.01%)
*2
*2
1
1
0.01Hz
0.1V
0.01Hz
0.1V
0.01Hz
0.1V
0.01Hz
0.1V
0.01Hz
0.1V
0.1/0.01s
0.1/0.01s
0.1%
0.01Hz
0.1%
0.01Hz
0.01Hz
1
1
1
1
1
0.1s
1
1
0.01Hz
0.01Hz
Refer
Customer
Initial Value
to
Setting
Page
9999
55
9999
55
9999
55
200/400V
55
60Hz
55
9999
55
9999
55
9999
55
9999
55
9999
55
9999
55
0
56
0
55
9999
56
0V
56
9999
56
0V
56
9999
56
0V
56
9999
56
0V
56
9999
56
0V
56
9999
43
9999
43
9999
42
9999
42
150%
44
0
44
60Hz
47
0
56
192
56
1
56
2
56
1
56
9999
56
9999
56
1
56
60Hz
57
60Hz
57