Selection of action conditions of the second
function signal (RT) and third function signal (X9)
Pr.155
RT signal reflection condition selection
You can select the second (third) function using RT (X9) signal.
You can also set the RT (X9) signal operation condition (reflection time).
Pr.155 Setting
These functions are immediately made valid
0 (initial value)
with on of the RT signal.
These functions are valid only during the RT
10
signal is on and constant speed operation.
(invalid during acceleration/deceleration)
⋅ Funtions which can be set as second and third function
Function
Function
Parameter
Torque boost
Base frequency
Acceleration time
Deceleration time
Electronic thermal
O/L relay
Stall prevention
Applied motor
Pr.80 to Pr.84,
Motor constants
Pr.90 to Pr.94,
Motor control method
Pr.800
Analog input filter
Pr.822, Pr.826
Pr.820, Pr.821,
Gain adjustment
Pr.824, Pr.825
Speed detection filter
Pr.823
Pr.
Pr.
156, 157
Refer to the section about Pr.22.
Pr.
Pr.
158
Refer to the section about Pr.52.
Pr.
Pr.
159
Refer to the section about Pr.135.
Pr.
Pr.
160, 172 to 174

User group function

Pr.160 User group read selection
Pr.173 User group registration
Parameter which can be read from the operation panel and
parameter unit can be restricted.
The inverter is set to display all parameters with initial setting.
Pr.160 Setting
0
All parameters can be displayed.
(initial value)
Only the parameters registered in the user group can
1
be displayed.
9999
Only the simple mode parameters can be displayed.
User group function (Pr.160, Pr.172 to Pr.174)
⋅ The user group function is designed to display only the
parameters necessary for setting.
⋅ From among all parameters, a maximum of 16 parameters can be
registered in the user group. When "1" is set in Pr.160 , only
parameters registered in the user group can be accessed for
reading and writing. (The parameters not registered in the user
group can not be read.)
T
o set a parameter in the user group, set its parameter number in
Pr.173.
⋅ To delete a parameter from the user group, set its parameter
number in Pr.174 . To batch-delete the registered parameters, set
Pr.172 to "9999".
59
When setting parameters, refer to the instruction manual (applied) and understand instructions.
Description
First
Second
Third
Function
Function
Parameter
Parameter
Pr.0
Pr.46
Pr.112
Pr.3
Pr.47
Pr.113
Pr.7
Pr.44
Pr.110
Pr.8
Pr.44, Pr.45
Pr.110, Pr.111
Pr. 9
Pr.51
Pr.22
Pr.48, Pr.49
Pr.114, Pr.115
Pr. 71
Pr. 450
Pr.453 to Pr.457
Pr.89
Pr.569,
Pr.458 to Pr.462,
Pr.96
Pr.463
Pr.451
Pr.832, Pr.836
Pr.830, Pr.831,
Pr.834, Pr.835
Pr.833
Pr.172 User group registered display/batch clear
Pr.174 User group clear
Description
Pr.
Pr.
161

Operation selection of the operation panel

Pr.161 Frequency setting/key lock operation selection
You can use the setting dial of the operation panel (FR-DU07) like
a potentiometer to perform operation.
The key operation of the operation panel can be disabled.
Pr.161 Setting
0 (initial value)
1
10
11
Pr.
Pr.
162 to 165
Pr.
Pr.
166, 167
Pr.
Pr.
168, 169
Pr.
Pr.
170, 171
Pr.
Pr.
172 to 174
Description
Setting dial frequency setting mode
Setting dial potentiometer mode
Setting dial frequency setting mode
Setting dial potentiometer mode
Refer to the section about Pr.57.
Refer to the section about Pr.150.
Parameter for manufacturer setting. Do not set.
Refer to the section about Pr.52.
Refer to the section about Pr.160.
Key lock mode
invalid
Key lock mode
valid