Siemens 181 Workshop Manual page 58

Analog input module ai 4xrtd/tc 2-/3-/4-wire hf (6es7134-6jd00-0ca1)
Table of Contents

Advertisement

Codes for measuring range
The following table contains the codes for the measuring ranges of the analog input module.
You must enter these codes at byte x+1 (see previous figure).
Table A- 4
Measuring range
Voltage
50 mV
80 mV
250 mV
1 V
Resistor
150 Ω
300 Ω
600 Ω
3 kΩ
6 kΩ
PTC
Thermal resistor climatic
Pt 100
Pt 200
Pt 500
Pt 1000
Thermal resistor standard
Pt 100
Pt 200
Pt 500
Pt 1000
Thermal resistor climatic
Ni 100
Ni 120
Ni 200
Ni 500
Ni 1000
LG-Ni 1000
Thermal resistor standard
Ni 100
Ni 120
Ni 200
Ni 500
Ni 1000
LG-Ni 1000
Analog input module AI 4xRTD/TC 2-/3-/4-wire HF (6ES7134-6JD00-0CA1)
Manual, 02/2014, A5E03573289-AD
A.2 Parameter assignment and structure of parameter data record
Codes for measuring range
Code
0000 0001
0000 0010
0000 0011
0000 0101
0000 0001
0000 0010
0000 0011
0000 0100
0000 0101
0000 1111
0000 0000
0000 0111
0000 1000
0000 1001
0000 0010
0000 1011
0000 0100
0000 0101
0000 0001
0000 1101
0001 0001
0001 0011
0000 1010
0001 1101
0000 0011
0000 1100
0001 0000
0001 0010
0000 0110
0001 1100