Motorola MK3000 Product Reference Manual page 63

Microkiosk for windows ce 5.0
Hide thumbs Also See for MK3000:
Table of Contents

Advertisement

IPL Errors (Continued)
Table 5-4
Error Text
Invalid data in HEX file
Exceeded max size
Partition is not valid on
this device
Wrong destination code
File type does not support
IPL Auto Select
Non-contiguous record
found
Timed Out - No data
Fail: Buffer Overrun
Partition Table not Valid
Invalid file format
Creating a Splash Screen
The DCP for MK3000 includes the source bitmap files that create the default splash screens. You can
customize the screen by modifying these files using any of the standard windows image editors.
To create a custom splash screen:
Use an image editor to open the Splashcolor.bmp file included with the DCP for MK3000.
1.
Modify the bitmap file and save.
2.
Create a splash partition. See
3.
If you don't use the default files to create the new splash screens, be sure to preserve the image format of 320
x 216, 8 bits per pixel. Note that 8 bits per pixel only applies to splash screen images. Once Windows CE is
running, the color density is 16 bits per pixel. See
information about loading the splash screen using TCM.
Error
Number
-25
The Symbol HEX file being downloaded contains invalid data.
Ensure the file is in proper Symbol HEX file format with valid HEX
data.
-26
The download file is too large to fit into the space allocated for it.
Either make the file smaller or increase the space allocated for it by
altering the partition table.
-27
The downloaded file specifies a partition entry that does not exist on
the device. Only download files that are valid for this device, or
change the partition table so that the new file is valid on the device.
-28
A specific partition was chosen from the Main Menu (not Auto
Select) but the file selected for download was for another partition.
Ensure that the partition selected from the Main Menu matches the
file selected for download.
-29
Monitor, Power Micro and Partition Table cannot be loaded with Auto
Select. Select the appropriate area, and try again.
-30
A Symbol HEX file download was attempted but the HEX file is
invalid. Ensure the file is in Symbol HEX file format.
-31
IPL was waiting for data from the source device but timed out before
receiving any. Check the source device connectivity and retry.
-32
The serial port device could not keep up with incoming data. Retry
the serial download with a lower baud rate.
-33
The size of flash memory is different than that described in the
partition table. Retry the download with the correct partition table file.
-34
The file format is invalid. Only Symbol HEX files are supported by
IPL.
Building the Image on page
Downloading the Image using IPL on page 5-14
Application Deployment 5 - 21
Probable Cause
5-12.
for

Hide quick links:

Advertisement

Table of Contents
loading