Pairing Methods
There are two pairing methods. The default method allows the linear imager scanner and cradle to pair
(connect) when the pairing bar code on the cradle is scanned. A second method pairs the linear imager
scanner and cradle when the linear imager scanner is inserted in the cradle. To enable this feature, scan
Enable Pair On Contacts below. With this feature enabled it is not necessary to scan the pairing bar code on
the cradle. If the pairing is successful, a low/high connection beep sequence sounds a few seconds after the
linear imager scanner is placed in the cradle. See
sequences.
To enable or disable pairing on contacts, scan the appropriate bar code below.
*
Enable Pair On Contacts
Unpairing
Unpair the linear imager scanner from the cradle or PC/host to make the cradle available for pairing with
another linear imager scanner. Scan the bar code below to disconnect the linear imager scanner from its
cradle/PC host.
An unpairing bar code is also included in the LI4278 Quick Reference Guide.
Unpairing
Pairing Bar Code Format
When the linear imager scanner is configured as an SPP Master, you must create a pairing bar code for the
remote Bluetooth device to which the linear imager scanner can connect. The Bluetooth address of the remote
device must be known. Pairing bar codes are Code 128 bar codes and are formatted as follows:
<Fnc 3>Bxxxxxxxxxxxx
where:
•
B (or LNKB) is the prefix
•
xxxxxxxxxxxx represents the 12-character Bluetooth address.
RADIO COMMUNICATIONS 4 - 21
Wireless Beeper Definitions on page 4-3
Disable Pair on Contacts
for other beep