CHAPTER 1 Product Overview
1.3 PRIMEQUEST 2000 series configuration
Virtual media function
Redundancy supported hardware
Hot replacement supported components PSU, fan, HDD
Number of installed MMBs
Input voltage
Number of installed PSUs (maximum)
Power redundancy support
External
dimensions [mm
(in.)]
Number of occupied units
Weight [kg(lb)]
*1: Since supported CPU differs depending on PRIMEQUEST model, see
*2: Since these values differ depending on CPU model, see
*3: When the maximum number of PCI_Boxes are connected.
*4: The KVM interface is provided for each SB (should not be always-on connection).
*5: Redundancy of MMB is supported in PRIMEQUEST 2400E and 2800E. PRIMEQUEST 2800B does not
support MMB redundancy.
For details on the device specifications, environment conditions and power conditions of the PRIMEQUEST
2000 series, see PRIMEQUEST 2000 series hardware installation manual (C122-H007EN).

1.3.3 Partition management

Partition is a divided unit of the hardware which is provided with the functions of processing device, having at
least one SB and IOU. Since partitions are independent hardware units, each partition can be considered as
an independent server. Multiple production system can be operated on a PRIMEQUEST 2000 by installing
different OS and applications in each partition.
The configuration of a partition of the PRIMEQUEST 2000 series can be changed by static configuration
control function (*1), and by dynamic configuration control function (*2).
*1: Function that turns on or turns off power in a partition unit, or changes its configuration triggered by
rebooting.
*2: Dynamic Reconfiguration (DR). Function which changes the partition resource configuration without
rebooting the partition which is the target for changing configuration.
For details on the partition functions, see

1.3.4 Hardware management

The Management Board (MMB) is provided as a mechanism for managing the hardware of the entire
PRIMEQUEST 2000 series.
The MMB console (*1), the Field Support Tool (FST (*2)), and an external network can be connected
through a LAN connection from the MMB.
*1: Console for setting up and displaying each hardware resource
*2: Console for maintaining the hardware of the PRIMEQUEST 2000 series. Used by the field engineers.
The MMB has dedicated CPU which is independent of the CPU on the SB, and is mounted on the rear of the
cabinet.
The MMB controls and processes the following.
-
Partition configuration control in cabinet
-
Power control
-
Mirror mode settings
TABLE 1.1 Hardware specifications (continued)
Supported
PSU, fan, HDD, PCI Express card, CLK, MMB (*5), power
input system
1 (Duplication is an option)
AC100 V/ 200-240
V
4 (200 V), 6 (100
V)
N+1, N+N (Dual power feed)
Width
445 (17.52)
Depth
782 (30.79)
Height
438 (17.25)
10U
124 (273)
'4.2.5 Partition settings and configuration
PRIMEQUEST
2400E
2800E
AC200-240 V
6
150 (331)
'2.3.1 Support CPU
11
2800B
1 (Duplication not
supported)
143 (315)
'2.3.1 Support CPU
list'.