Event notification messages do not appear on
console screen
Action: If you are using SLES 9, upgrade the KDE or use a different desktop, such as GNOME.
Event notifications are not being sent
Action: While email and SNMP trap notifications must be set up on their respective screens, notifications
must also be enabled per event on the Event Notifications screen
64).
FTP error messages appear when connecting
through Linux
Symptom: When connecting to FTP through Linux, error messages about bad commands appear.
Action: The user can log in although the error messages appear.
Flash update fails over a serial connection
Action: Disable any serial port being configured during the flash update, such as iLO, or use an FTP
connection.
HP SIM lists a discovered UPS as Unmanaged in the
System Type column
Action:
Delete the discovered UPS from HP SIM.
1.
Using the management module web interface, add the HP SIM server as a Manager on the SNMP
2.
Managers tab (on page 62).
Rediscover the UPS in HP SIM.
3.
LED flash error code
Permanently on
2 flashes
3 flashes
4 flashes
5 flashes
6 flashes
Description
DRAM failure
DMA Mem to Mem error
IRQ error
Ethernet error
Serial loop back error
RTC error
("Event Notifications
menu" on page