Whirlpool AMC 996 Instructions For Use Manual

Whirlpool AMC 996 Instructions For Use Manual

Single split air conditioner with gas r410a / r410a inverter

Advertisement

32602005GB.fm Page 29 Thursday, December 14, 2006 11:24 AM

INSTRUCTIONS FOR USE

SINGLE SPLIT AIR CONDITIONER WITH
GAS R410A / R410A INVERTER
PRECAUTIONS FOR USE
SPECIFICATIONS AND TECHNICAL DATA
(DEPENDING ON THE MODEL)
INSTRUCTIONS FOR USE
DESCRIPTION OF AIR CONDITIONER
COMPONENTS
HOW TO USE REMOTE CONTROL

CLEANING AND MAINTENANCE

TROUBLESHOOTING

INSTALLATION SERVICE - PRECAUTIONS
ON INSTALLATION

ELECTRICAL SAFETY REQUIREMENTS

INSTALLATION DIMENSION DRAWINGS

INSTALLING INDOOR UNIT

CHECKS AND TEST RUN AFTER INSTALLATION
ELECTRIC HEATING BELT

ELECTRICAL CONNECTION

Thank you for selecting a Whirlpool air conditioner. For best results, please keep this Manual properly for
future reference.
This appliance is marked according to the European directive 2002/96/EC on Waste Electrical and Electronic
Equipment (WEEE).
By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for
the environment and human health, which could otherwise be caused by inappropriate waste handling of this
product.
The symbol
on the product, or on the documents accompanying the product, indicates that this
appliance may not be treated as household waste. Instead it shall be handed over to the applicable collection
point for the recycling of electrical and electronic equipment.
Disposal must be carried out in accordance with local environmental regulations for waste disposal.
For more detailed information about treatment, recovery and recycling of this product, please contact your
local city office, your household waste disposal service or the shop where you purchased the product.
29

Advertisement

Table of Contents
loading

Summary of Contents for Whirlpool AMC 996

  • Page 1: Instructions For Use

    CHECKS AND TEST RUN AFTER INSTALLATION ELECTRIC HEATING BELT ELECTRICAL CONNECTION Thank you for selecting a Whirlpool air conditioner. For best results, please keep this Manual properly for future reference. This appliance is marked according to the European directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE).
  • Page 2: Precautions For Use

    • If you notice anything unusual (e.g. burnt smell), switch off the power supply immediately and contact the Whirlpool Authorized Service Center nearest you. If the abnormal condition continues, the air conditioner could be damaged and could also cause electrocution or fire.
  • Page 3 32602005GB.fm Page 31 Thursday, December 14, 2006 11:24 AM Warning: • Do not cut or damage the power cords and control lines. Any damaged power cords and signal control lines of the air conditioner must be replaced by qualified technicians with special cords. •...
  • Page 4: Specifications And Technical Data

    2. When the unit is started again after a stop, it automatically resumes in the same mode as when it was stopped. The outdoor unit starts after a slight delay. Working temperature range: Working temperature range AMC 996, AMC 998 Inside Temp Outside Temp DB/WB (°C)
  • Page 5 32602005GB.fm Page 33 Thursday, December 14, 2006 11:24 AM INSTRUCTIONS FOR USE The Principle and Special Functions of Cooling Mode Principle: The air conditioner absorbs heat from indoor air and discharges it outdoors, thus lowering the indoor room temperature. Cooling capacity decreases with a rise in outdoor temperatures.
  • Page 6: Description Of Air Conditioner Components

    32602005GB.fm Page 34 Thursday, December 14, 2006 11:24 AM DESCRIPTION OF AIR CONDITIONER COMPONENTS Indoor Unit AMC 996 with INVERTER AMC 998 with INVERTER Air inlet Air outlet Remote Control 1. Power plug 2. Terminal board cover plate 3. Key switch 4.
  • Page 7 32602005GB.fm Page 35 Thursday, December 14, 2006 11:24 AM Indoor Unit AMC 994 Air inlet Air outlet Remote Control 1. Key switch 2. Front panel 3. Filter 4. Guide louver 5. Receiving windows 6. LED Board 7. Wall pipe 8. Wrapping Tape 9.
  • Page 8 32602005GB.fm Page 36 Thursday, December 14, 2006 11:24 AM Indoor Unit AMC 990 Air inlet Air outlet 1. Power plug 2. Key switch 3. Front panel 4. Guide louver 5. Filter 6. Remote control windows 7. Covering plate of Terminal Board Outdoor Unit 8.
  • Page 9 32602005GB.fm Page 37 Thursday, December 14, 2006 11:24 AM Indoor Unit AMC 991 AMC 992 AMC 993 Air inlet Air outlet 1. Power plug 2. Key switch 3. Front panel 4. Guide louver 5. Filter 6. Remote control windows 7. Covering plate of Terminal Board Outdoor Unit 8.
  • Page 10: How To Use Remote Control

    32602005GB.fm Page 38 Thursday, December 14, 2006 11:24 AM HOW TO USE REMOTE CONTROL Operating Guideline - General Procedures 1. After the main unit is connected to power, press the ON/OFF key on the remote control to start the air conditioner. (Note: The guide louver on main unit will be closed automatically when the air conditioner is switched off).
  • Page 11 32602005GB.fm Page 39 Thursday, December 14, 2006 11:24 AM UP/DOWN UP/DOWN Key Press these two keys when in COOL, DRY, FAN or HEAT mode to set a temperature between 16 and 30°C. The temperature of each mode can be stored. FAN SPEED FAN Key Press this key to change the fan speed cyclically as follows:...
  • Page 12 32602005GB.fm Page 40 Thursday, December 14, 2006 11:24 AM JET key In COOL or HEAT mode, press this key to activate or disable the jet function. The JET icon will appear when the jet function is activated. The jet function will be automatically cancelled upon change of mode or fan speed.
  • Page 13 1 second. On receipt of the message, the main unit will emit a beep. Emergency Operation (on models AMC 996 and AMC 998) If your remote control is lost or damaged, you can use the 6th Sense /STOP key, in which case the unit will run in auto mode and you cannot change the preset temperature and fan speed.
  • Page 14: Cleaning And Maintenance

    32602005GB.fm Page 42 Thursday, December 14, 2006 11:24 AM CLEANING AND MAINTENANCE Warning • Make sure to stop the unit and unplug it before cleaning your air conditioner. Otherwise you may risk electrocution. • Wetting of air conditioner may cause the risk of electrocution. Never wash your air conditioner.
  • Page 15 2. Check the grounding cable for reliability. 3. Check the battery of the remote control for replacement. 4. Check the mounting frame of the outdoor unit for damage. If damaged, contact a Whirlpool Authorized Service Center. Maintenance after Seasonal Use 1. Disconnect from the power supply.
  • Page 16: Troubleshooting

    Warning: Do not attempt to repair the air conditioner yourself. Incorrect repairs may cause electrocution or fire, so please contact the Whirlpool Authorized Service Center nearest you for professional repairs. The following checks may save your time and costs. Malfunction...
  • Page 17 If the air conditioner is left running in high humidity, moisture may condense on the grill and accumulate there. In case of the following events, please contact the Whirlpool Authorized Service Center nearest you. Stop the air conditioner and pull •...
  • Page 18 7. Choose a place where that the air filter can be easily accessed; 2. Contact the local Whirlpool Service Center or qualified technician before installation 8. Ensure the installation of indoor unit is in conformity with the requirements of the 3.
  • Page 19: Electrical Safety Requirements

    1.5m. Model Capacity of air Min. section of Min. section of grounding cable power cable break switch AMC 996 1.0M2 1.5M2 AMC 998 1.5M2 1.5M2 Notes: • The live wire, neutral wire and grounding wire inside the power socket must be connected. Connect these wires correctly and reliably without short circuit.
  • Page 20 32602005GB.fm Page 48 Thursday, December 14, 2006 11:24 AM INSTALLATION DIMENSION DRAWINGS AMC 990 AMC 991 AMC 992 AMC 993 AMC 994 AMC 996 AMC 998 From the ceiling Over 15cm From the Wall Over 15cm Over 15cm From the Wall...
  • Page 21: Installing Indoor Unit

    32602005GB.fm Page 49 Thursday, December 14, 2006 11:24 AM INSTALLING INDOOR UNIT Installing Wall-Mount Frame 1. Level with plumb line or spirit level. As the drain outlet is on the left side, it is better for the left side to be lower when adjusting the wall-mounted board.
  • Page 22 32602005GB.fm Page 50 Thursday, December 14, 2006 11:24 AM Notes: If the connecting cable is not long enough, please contact the authorized service center for a length of special cable. No joints are allowed in the cable. • Make sure to connect the cable correctly. Incorrect connection will cause malfunction of some electrical parts.
  • Page 23 Brown Yellow-Green Connection Brown Wire Blue Black Yellow-Green Power Air purging and Outdoor unit terminal board Connection leakage test Wire Clamp Wire AMC 996/8 Handle Brown Power Blue Yellow-Green Connection Black Cable Blue Yellow-Green Brown Black Power Connection Cable Clamp...
  • Page 24 32602005GB.fm Page 52 Thursday, December 14, 2006 11:24 AM Vacuum-pumping and Leakage Inspection Vacuum Gauge Small Pipe 1. Remove the nut cover at the shutoff valve. 2. Align with the center of the fitting pipe and manually tighten Big Pipe the conical nut sufficiently.
  • Page 25 • Press the Mode key, select the operating modes such as cooling and fan, and check for normal operation. ELECTRIC HEATING BELT ELECTRIC HEATING BELT FOR INVERTER MODEL AMC 996, AMC 998 ONLY In case of malfunction of the outdoor temperature sensor, both electric belts stop working. Under normal conditions, operations is as follows: 1.
  • Page 26: Electrical Connection

    3) Socket outlet / plug (valid for both countries) If the fitted plug is not suitable for your socket outlet, please contact Whirlpool Service for further instruction. Please do not attempt to change plug yourself. This procedure needs to be carried out by a qualified Whirlpool technician in compliance with the manufactures instructions and current standard safety regulations.

Table of Contents