Siemens FI18NP Series Operating Instructions Manual page 20

Freezer
Hide thumbs Also See for FI18NP Series:
Table of Contents

Advertisement

The ice maker does
The appliance or ice maker has only just been
not make enough
switched on.
ice or the ice is
A lot of ice has been taken.
deformed.
Low water pressure.
The water filter is bunged up or used.
The ice maker does
The ice maker is switched off.
not make any ice.
The appliance is not supplied with water.
Water supply has kinks.
Low water pressure.
Temperature in the freezer space is too high.
Ice cube container is not properly inserted.
Incorrect shut-off tap installed.
Condensation forms
The ice maker is switched off.
on the discharge
The condensation heating is deactivated.
unit of the
dispenser.
Filter exchange
Water filter cartridge must be exchanged.
message appears
in the display.
After exchanging the filter the filter exchange
display is not reset.
The illumination on
The bulb is defective.
the dispenser unit
does not work.
The permanent light function is deactivated.
Ice forms in the
Low water pressure.
inflow hose to the
ice maker.
Shut off tap incorrectly opened.
Temperature in the freezer space is too high.
20
Approx. 24 hours is needed until ice production
starts.
Approx. 24 hours is needed until the ice cube
container is filled again.
The water pressure must be between 1.72 bar
and 8.25 bar so that the appliance works
properly.
Change the water filter.
Switch the ice maker on at the control panel.
Contact the installer or the water supply
company.
Turn off the water supply at the shut-off tap.
Smoothen out the kinks, exchange where
necessary.
The water pressure must be between 1.72 bar
and 8.25 bar so that the appliance works
properly.
Temperature in the freezer space should lie
between
17 and
18 °C, adjust where
necessary.
Check the position, re-insert where necessary.
Incorrect taps can cause low water pressure and
damage to the appliance.
To switch the condensation heating on:
Switch on the ice maker.
Press the lock button and the agitation
button simultaneously and keep pressed for
3 seconds. The water button and ice cube
button flash twice.
The ice maker is switched off, but the
condensation heating function keeps working.
To switch the condensation heating off:
Press the lock button and the agitation
button simultaneously and keep pressed for
3 seconds. The water button and ice cube
button flash once.
Exchange filter cartridge. If no new filter is
available, insert bypass cap.
Reset filter exchange display.
Replace bulb (see "Changing light bulbs",
page 22).
Press the light button in order to switch the
permanent light function on.
The water pressure must be between 1.72 bar
and 8.25 bar so that the appliance works
properly.
Open shut off tap fully.
Temperature in the freezer space should lie
between
17 and
18 °C, adjust where
necessary.