Water runs from
The water connection hose is not properly
the appliance.
sealed.
Incorrect shut-off tap installed.
The water pressure
Low water pressure.
is less than usual.
Shut off tap incorrectly opened.
Incorrect shut-off tap installed.
Water supply has kinks.
The water filter is bunged up or used.
The discharged
The appliance is newly set up.
water is not cold.
The water in the tank is exposed.
The water has stood for a long period in the
pipes outside of the tank and has adapted to the
room temperature.
The water appears
There is air or air bubbles in the water.
cloudy.
Particles float in the
The first water which runs through the filter can
water or ice cubes.
rinse carbon dust out of the filter.
If water freezes and thaws again, particles are
formed by mineral deposits.
Replace the hose with a manufacturer's original
part.
Incorrect taps can cause low water pressure
and damage to the appliance.
The water pressure must be between 1.72 bar
and 8.25 bar so that the appliance works
properly.
Open shut off tap fully and check for leaks.
Check the minimum through flow.
Incorrect taps can cause low water pressure
and damage to the appliance.
Turn off the water supply at the shut-off tap.
Smoothen out the kinks, exchange where
necessary.
Change the water filter.
The water in the tank needs approx.12 hours
to cool down.
Throw the first glass of water away.
This is normal when using the dispenser for
the first time. It disappears after a short time.
The particles are not harmful! These particles
disappear after a short period.
The particles are not harmful! In the water supply
this is a natural occurrence.