Start-Up, Adjustments And Checks; Wgge45 - Whirlpool Gold WGGE45 Installation Instructions Manual

Whirlpool gold models package gas electric furnaces
Table of Contents

Advertisement

Sizing Between Single or 2
Maximum propane capacities listed are based on ¹⁄₂" W.C. pressure drop at 11" W.C. setting. Capacities in 1,000 Btu/h.
Propane Gas Piping Chart II
Pipe or Tubing Length—ft (m)
10 (3)
20 (6.1)
30 (9.2)
40 (12.2)
50 (15.2)
60 (18.3)
80 (24.4)
100 (30.5)
125 (38.1)
150 (45.7)
200 (61)
250 (76.2)
300
350
400
Data in accordance with NFPA pamphlet Number 54.
WARNING
To prevent property damage or serious personal injury
due to fire or explosion caused by a propane gas leak,
Goodman 102
install a gas detecting warning device.
If the propane gas unit is installed in an excavated area
or a confined space, a warning device is required due to:
-Propane gas is heavier than air and any leaking gas
can settle in any low areas or confined spaces.
-Propane gas odorant may fade, making the gas
undetectable except with a warning device.

Start-up, Adjustments and Checks

Heating Start-up
This unit is equipped with an electronic ignition device to
automatically light the main burners. It also has a power vent
blower to exhaust combustion products.
On new installations, or if a major component has been replaced,
the operation of the unit must be checked.
Check unit operation as outlined in the following instructions. If
any sparking, odors or unusual sounds are encountered, turn off
electrical power and recheck for wiring errors or obstructions in
or near the blower motors. Duct covers must be removed before
operating unit.
Heat Anticipator Setting
Set the heat anticipator on the room thermostat to 0.4 amps to
obtain the proper number of heating cycles per hour and to
prevent the room temperature from overshooting the room
thermostat setting.
14
nd
Stage Regulator and Appliance*
Tubing Size, O.D. Type L
³⁄₈"
¹⁄₂"
⁵⁄₈"
49
110
206
34
76
141
27
61
114
23
52
97
20
46
86
19
42
78
16
36
67
14
32
59
12
28
52
11
26
48
10
22
41
9
19
36
8
18
33
7
16
30
7
15
28
Nominal Pipe Size Schedule 40
³⁄₄"
⁷⁄₈"
¹⁄₂"
348
539
291
239
368
200
192
296
161
164
253
137
146
224
122
132
203
110
113
174
94
100
154
84
89
137
74
80
124
67
69
106
58
61
94
51
55
85
46
51
78
43
47
73
40
Rollout Protection Control
The rollout protection device opens, cutting power to the gas
control valve, if the flames from the burners are not properly
drawn into the heat exchanger. The rollout protection device is
located on the burner bracket. The reason for elevated
temperatures at the control should be determined and repaired
prior to resetting this manual reset control.
WARNING
To avoid property damage, personal injury or death due
to fire or explosion, a qualified servicer must investigate
the reason for the rollout protection device to open
before manually resetting the rollout protection device.
Rollout Protection on Burner Bracket
A. Rollout protection
³⁄₄"
1"
1¹⁄₄"
608
1,146
2,353
418
788
1,617
336
632
1,299
284
541
1,111
255
480
985
231
436
892
198
372
764
175
330
677
155
292
600
141
265
544
120
227
465
107
201
412
97
182
374
89
167
344
83
156
320
Goodman 94
A
1¹⁄₂"
3,525
2,423
1,946
1,665
1,476
1,337
1,144
1,014
899
815
697
618
560
515
479