Reassembly can be accomplished by following the disassembly procedures in reverse. However, special
attention should be given to the following items.
1. Mounting the change knob
Mount Spring (C) [49] and the Steel Ball D3.97 [50] into the Change Knob [48] as shown in the figure
below.
Mounting the change knob
Steel Ball D3.97 [50]
Retaining Ring (E-Type)
for D5 Shaft [39]
2. Mounting the gear holder
Before mounting the Roller Holder [44], be sure to insert the Needle Roller [43] into the designated position
of the Gear Holder [38] because the Needle Roller [43] cannot be inserted after mounting the Roller Holder
[44].
Mounting the gear holder
Gear Holder [38]
Reassembly
Spring (C) [49]
Change Knob [48]
Needle Roller [43]
Roller Holder [44]
-20-