Power Supply Leds - HP 9030 CE Handbook

Hp 9000 series 500 computers models 530/540
Hide thumbs Also See for 9030 CE:
Table of Contents

Advertisement

5-6 9030140 Diagnostics
Power Supply LEDs
LED
Indication When lit
Cure
DOORS OPEN
Interface card cage door or processor
Close door(sl, tighten thumbscrews.
stack door is open. OV also lights.
STACK TEMP
Processor stack temperature has ex-
Check ambient air temperature, airflow,
ceeded lOO°e.
fans, power supply assembly.
SEC BOARD
+
12MM mass storage power supply
Check
+
12MM mass storage power
has failed or temperature in power
supply and bus, ambient air tempera-
supply assembly has exceeded 100°e.
ture, airflow, fans, power supply
assembly.
PWR
Peak primary current exceeded 9A.
Check power supply assembly, short
circuits.
OV
Used in conjunction with voltage LEOs:
Close door(s), tighten thumbscrews.
"on" indicates an overvoltage condition Check power supply assembly, short or
on one or more of the supplies or door
open circuits.
open. "off' indicates an undervoltage
condition.
-19
Fault condition exists on the indicated
Check power supply assembly, lOP
-12
supply. If the OV LED is also lit, an
bus, modules using the indicated vol-
-2
overvoltage condition is indicated: if OV tage, short or open circuits.
3
is not lit. an undervoltage condition is
5
indicated.
6
12
19
System Functional Tests (SFT)
1. If not previously done. install and verify the HP-UX operating system.
2. In response to the
log in:
prompt, type:
roo
t
and press (
RETURN).
You are now the
super-user.
3. Type:
cd Ius r/ptests.
4. Type:
s tar t
and press (
RETURN).
5. From the menu that appears on the system console, select the test you would like to run,
enter its number, and press (
RETURN).

Advertisement

Table of Contents
loading

This manual is also suitable for:

9040 ce9040530540

Table of Contents