Safety Information - Pioneer MJ-L5 Service Manual

Minidisc recorder/surround processor
Hide thumbs Also See for MJ-L5:
Table of Contents

Advertisement

MJ-L5, SP-L5

1. SAFETY INFORMATION

This service manual is intended for qualified service technicians; it is not meant for the casual
do-it-yourselfer. Qualified technicians have the necessary test equipment and tools, and have been
trained to properly and safely repair complex products such as those covered by this manual.
Improperly performed repairs can adversely affect the safety and reliability of the product and may
void the warranty. If you are not qualified to perform the repair of this product properly and safely, you
should not risk trying to do so and refer the repair to a qualified service technician.
WARNING
This product contains lead in solder and certain electrical parts contain chemicals which are known to the state of California to
cause cancer, birth defects or other reproductive harm.
THIS PIONEER APPARATUS CONTAINS
LASER OF CLASS 1.
SERVICING OPERATION OF THE APPARATUS
S H O U L D B E D O N E B Y A S P E C I A L L Y
INSTRUTED PERSON.
LABEL CHECK ( for MJ-L5/MYXK and NVXK only )
MJ-L5/MYXK
MJ-L5/NVXK
2
IMPORTANT
Printed on the Rear Panel
Health & Safety Code Section 25249.6 – Proposition 65
LASER DIODE CHARACTERISTICS
MAXIMUM OUTPUT POWER: 32 mw
WAVELENGTH: 785 nm
Additional Laser Caution
Laser pickup assy
The output power at the objective lens of this assy is 0.73 mW.
Control method of the current through a laser diode.
The resistor R105 on the MD CORE MAIN UNIT (For MD
mechanism assy) are for the limiting of current through a laser
diode.
Control method of the laser output power
The laser pickup assy provide the photo-diodes and APC (Auto
Power Control) circuit.
The photo-diode detect output of the laser diode then IC104 control
the APC circuit according to the signal voltage of the photo-diode via
IC101.
The Variable resistancer on the FPC in the Laser pickup assy can
be adjusted the output level of Laser diode to fix the rated output
level.
Laser Interlock Switch
The loading position detect switch S101 is set to " LOAD ON " (ON:
low level, OFF: high level) position, IC104 get the " LOAD " signal,
and hand the laser " LDON " signal to No. 9 terminal (LDON) of the
Laser pickup assy.
Then a laser diode can be lighted exept when the level of signal
"LOAD " is low.
∗ Refer to page 50.