Dialing Function Does Not Switch Between "Tone" And "Pulse; A Communication Error Occurs; Reception Mode Cannot Be Changed; Caller Id Are Not Displayed - Brother DCP-9055CDN Service Manual

Color laser mfc
Hide thumbs Also See for DCP-9055CDN:
Table of Contents

Advertisement

3.12.6 Dialing function does not switch between "Tone" and "Pulse"

Step
1
2
3

3.12.7 A communication error occurs

Step
1
2

3.12.8 Reception mode cannot be changed

Step
1

3.12.9 Caller ID are not displayed

Step
1
Cause
Connection between main
PCB and NCU PCB
NCU PCB failure
Main PCB failure
Cause
NCU PCB failure
Main PCB failure
Cause
The Distinctive ring mode is
set to ON
Cause
Main PCB failure
Connect the connector between the main
PCB ASSY and NCU PCB ASSY correctly.
Replace the NCU PCB ASSY.
Replace the main PCB ASSY.
Replace the NCU PCB ASSY.
Replace the main PCB ASSY.
Turn OFF the Distinctive ring mode.
Replace the main PCB ASSY.
2-137
Remedy
Remedy
Remedy
Remedy
Confidential