If the Power Cut Off mode is manually set to On during a scheduled power Off time, power
cut remains in the On state until the next power cut off time, or until the Power Cut Off mode
is manually set to Off.
Power Saving Mode
If the Multiline Terminal is idle or receives no incoming calls for the programmed period,
system activates the Power Saving mode. The Line Key and feature key LED's on the
Multiline Terminal will darken. This feature does not affect the terminal display.
The Power Saving mode can be individually set for each terminal.
Any key operation or incoming call at the terminal ends the Power Saving mode and all
LEDs will return to normal brightness.
Power Failure Saving Mode
The same conditions as Power Cut Off mode exists with the following exceptions:
When the system is in the Power Failure Saving mode, power must be restored to the system
before restoring power to the phones. When in a Power Failure Saving mode, a system reset
will not restore power to the multiline terminals.
Multiline Terminals can be assigned to cut power on a per station basis when the system
enters the Power Failure Saving mode. This feature does not support power save groups.
Default Settings
None
System Availability
Terminals
Multiline Terminal (DT300/ Dterm85)
Required Component(s)
CD-8DLCA/ CD-16DLCA or PZ-8DLCB or CD-LTA
V7000 Enhancement License (0036)
Related Features
Night Service