AP 7161 Access Point Installation Guide
Rotate the access point bracket section upward and align the top holes on the sides with the top holes on the angle adapter
6.
bracket section. Insert two M6 hex flange screws into the top holes on the angle adapter bracket section.
Use a torque wrench or a ratchet and a 10mm socket to finish attaching the access point bracket section to the angle adapter
7.
bracket section with the M6 hex flange screws in the open slot connections and the top holes on the angle adapter bracket
section. Do not tighten the screws until all rotation and tilt adjustments are complete.
To adjust the position of the access point, rotate the access point bracket section (plus or minus 15 degrees) and tilt the angle
8.
adapter bracket section (up to 45 degrees)
Tighten all hex flange screws to 60 inch pounds (lbf-in).
9.
To use the extension armwith the mounting hardware kit:
Attach the pole mount section at the desired mounting location using a U-bolt or band clamps.
1.
Complete the steps for assembling and positioning the mounting bracket sections for poles less than or greater than 3 inches
2.
outlined above.
Using a torque wrench or a ratchet and a 10mm socket, attach the extension arm to the access point bracket section with four
3.
M6 hex flange screws. Tighten the hex flange screws to 60 inch pounds (lbf-in).
With the access point positioned so that the gore vent is facing down, attach the extension arm to the access point with four
4.
M6 hex flange screws. Tighten the hex flange screws to 60 inch pounds (lbf-in).
Examples for using the extension arm alone, or with the mounting bracket kit for a pole mount installation are shown below.
25