Torque control by real sensorless vector
control, vector control
4.5.4

Torque command (Pr. 803 to Pr. 806)

Torque command source for torque control can be selected.
Parameter
Name
Number
Constant power range
803
torque characteristic
selection
Torque command
804
source selection
Torque command
805
value (RAM)
Torque command
806
value
(RAM,EEPROM)
(1) Control block diagram
Pr. 804 Torque command
source selection
Analog input
Parameter
1,3,5,6
(Pr. 805, Pr. 806)
16 bit digital input
(FR-A7AX)
(2) Torque command (Pr. 804 = "0" (initial value)) by analog input (terminal 1)
Torque command
150%
-100%
0
(-10V)
-150%
122
Initial
Setting
Value
Range
0
0
1
0
1
3
0
4
5
6
600 to
1000%
1400%
600 to
1000%
1400%
Speed estimated
value
0
4
+
Speed limit input
Speed estimated
-
value
Real sensorless vector control
100%
Terminal 1
+10V)
analog input
Sensorless
Sensorless
Sensorless
Vector
Vector
Vector
Description
Constant motor output
command
Constant torque command
Torque command by terminal1 analog input
(Refer to page 295)
Torque command by parameter setting (Pr. 805 or Pr. 806)
(-400% to 400%)
Torque command by
parameter setting
(Pr. 805 or Pr. 806)
(-400% to 400%)
12 bit/16 bit digital input (FR-A7AX)
Torque command by
parameter setting
(Pr. 805 or Pr. 806) with
using communication
other than CC-Link
communication
(-400% to 400%)
Writes the torque command value to the RAM.
On the assumption that 1000% is 0%, the torque command is set by
an offset from 1000%.
Writes the torque command value to the RAM and EEPROM.
On the assumption that 1000% is 0%, the torque command is set by
an offset from 1000%.
Speed limit value
+
-
Speed control
(proportional control)
Speed limit value
Speed estimator
Vector control
⋅ Torque command is given by voltage (current) input to
terminal 1.
⋅ When torque command is input from terminal 1, set "4 or
3" in Pr. 868 Terminal 1 function assignment.
⋅ Torque command by analog input can be calibrated using
calibration parameter C16 (Pr. 919) to C19 (Pr. 920) . (Refer
to page 295 )
Select the torque command in the
constant power region by torque
command setting.
Torque command with using CC-Link
communication (FR-A7NC)
Setting from the remote resister can be
made. (-400% to 400%)
Torque command with using CC-Link
communication (FR-A7NC)
Setting from the remote resister can be
made. (-327.68% to 327.67%)
Torque command with using CC-Link
communication (FR-A7NC)
(-327.68% to 327.67%)
Torque control
Motor
Encoder