Parameter List
Func-
Parameter
tion
41
Up-to-frequency sensitivity
42
Output frequency detection
Output frequency detection for reverse
43
rotation
44
Second acceleration/deceleration time
45
Second deceleration time
46
Second torque boost
47
Second V/F (base frequency)
Second stall prevention operation
48
current
Second stall prevention operation
49
frequency
50
Second output frequency detection
51
Second electronic thermal O/L relay
52
DU/PU main display data selection
54
FM terminal function selection
55
Frequency monitoring reference
56
Current monitoring reference
57
Restart coasting time
58
Restart cushion time
⎯
59
Remote function selection
⎯
60
Energy saving control selection
61
Reference current
62
Reference value at acceleration
63
Reference value at dcceleration
64
Starting frequency for elevator mode
⎯
65
Retry selection
Stall prevention operation reduction
⎯
66
starting frequency
67
Number of retries at alarm occurrence
68
Retry waiting time
69
Retry count display erase
⎯
70
Special regenerative brake duty
⎯
71
Applied motor
⎯
72
PWM frequency selection
⎯
73
Analog input selection
⎯
74
Input filter time constant
Reset selection/disconnected PU
⎯
75
detection/PU stop selection
⎯
76
Alarm code output selection
⎯
77
Parameter write selection
⎯
78
Reverse rotation prevention selection
⎯
79
Operation mode selection
72
Name
0 to 100%
0 to 400Hz
0 to 400Hz, 9999
0 to 3600/360s
0 to 3600/360s, 9999
0 to 30%, 9999
0 to 400Hz, 9999
0 to 220%
0 to 400Hz, 9999
0 to 400Hz
0 to 500A, 9999/
0 to 3600A, 9999
0, 5 to 14, 17 to 20,
22 to 25, 32 to 35,
50 to 57, 100
1 to 3, 5 to 14, 17, 18,
21, 24, 32 to 34, 50, 52,
53, 70
0 to 400Hz
0 to 500/0 to 3600A
0, 0.1 to 5s, 9999/
0, 0.1 to 30s, 9999
0 to 60s
0, 1, 2, 3
0, 4
0 to 500A, 9999/
0 to 3600A, 9999
0 to 220%, 9999
0 to 220%, 9999
0 to 10Hz, 9999
0 to 5
0 to 400Hz
0 to 10, 101 to 110
0 to 10s
0
0 to 30%/0 to 10%
0 to 8, 13 to 18, 20, 23,
24, 30, 33, 34, 40, 43, 44,
50, 53, 54
0 to 15/0 to 6, 25
0 to 7, 10 to 17
0 to 8
0 to 3, 14 to 17, 100 to
103, 114 to 117
0, 1, 2
0, 1, 2
0, 1, 2
0, 1, 2, 3, 4, 6, 7
Minimum
Setting Range
Setting
Increments
0.1%
0.01Hz
0.01Hz
0.1/0.01s
0.1/0.01s
0.1%
0.01Hz
0.1%
0.01Hz
0.01Hz
0.01/0.1A
*2
1
1
0.01Hz
0.01/0.1A
*2
0.1s
*2
0.1s
1
1
0.01A/0.1A
*2
0.1%
0.1%
0.01Hz
1
0.01Hz
1
0.1s
1
0.1%
*2
1
1
*2
1
1
1
1
1
1
1
Refer
Customer
Initial Value
to
Page
243
10%
243
6Hz
243
9999
5s
173
9999
173
9999
143
9999
159
150%
150
0Hz
150
30Hz
243
9999
181
*2
0
250
1
250
Hz
255
60
Rated inverter
255
*2
current
9999
261
1s
261
0
170
0
273
163,
9999
*2
179
9999
179
9999
179
9999
163
0
268
Hz
150
60
0
268
1s
268
0
268
0%
204
145,
0
185
2
279
1
285
1
287
14
302
0
270
0
305
0
306
0
308
Setting